Your Quick Search:
"Single Ref Point"
Software:
Total results: 160 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
| Card 97 View | Calculations (AutoCAD Based) | Reference Points | None | None | 1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location 2. New ref points in HydraCALC are not using the values of the HYD ref points. |
|
| Card 1403 View | HydraCALC (Revit Based) | All Ref Points | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 840 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | AutoCALC is creating extra node points where there shouldn't be. In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.
'extra node' 'extra ref point' 'extra reference point' 'refpt' |
|
| Card 1402 View | HydraCAD (Revit Based) | Pretty Sprinklers | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 1376 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | Error placing Reference Points or Demand Area annotation... The 3D view ownerDBViewId is not locked. |
|
| Card 11 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | 1a.1 | Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2
can also be Step 1a.4 |
|
| Card 391 View | Calculations (AutoCAD Based) | Dummy Reference Points | None | None | Dummy reference points cannot find the dummy ref point block in the drawing's block table. **Possible there's a missing registry entry** Dialog box 52.04 |
|
| Card 70 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Duplicated Hydraulic Ref Point |
Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID Duplicated hydraulic ref points
|
|
| Card 526 View | Calculations (AutoCAD Based) | Reference Points | None | None | Bad ref point block Dialog box |
|
| Card 1457 View | HydraCALC (Revit Based) | All Ref Points | None | System.Nullreferenceexception: | When trying to add reference points, none are added and this error shows:
|
|
| Card 1422 View | HydraCALC (Revit Based) | All Ref Points | None | System.Nullreferenceexception: | When trying to add reference points, none are added and this error shows:
|
|
| Card 1300 View | HydraCAD (Revit Based) | Spacing and Layout | Insert Sprinklers | Command Failure For External Command | Revit could not complete the external command... Object Reference not set to an instance of an object.
|
|
| Card 1406 View | HydraCALC (Standalone) | Print Final | None | When printing final, your outside hose demand after the pump isn't included in the total flow.
In the example above, the system demand is 1274 gpm is represented by point D2/D3. The outside hose adds up to another 250 gpm but there isn't another marker at 1524 gpm *Please note, while the Demand summary at the top shows D3 as a point, since D2 and D3 are the same value, the graph will only show point D2. |
||
| Card 1453 View | Launching HydraCAD (AutoCAD Based) | None | None | Unhandled Exception | When opening Hydracad you get the
following error: Unhandled exception has occurred
in a component in your application. If you click
Continue, the application will ignore this error and attempt to continue. Retrieving the COM class factory
for component with CLSID {44D62FAE-67A7-4131-BF38-489CDFE44738}
failed due to the following error: 80070005 Access
is denied. (Exception from HRESULT: 0x80070005
(E_ACCESSDENIED)). |
|
| Card 1452 View | Launching HydraCAD (AutoCAD Based) | None | None | Unhandled Exception | When opening Hydracad you get the following error:
Unhandled exception has occurred
in a component in your application. If you click
Continue, the application will ignore this error and attempt to
continue. Retrieving the COM class factory
for component with CLSID
{44D62FAE-67A7-4131-BF38-489CDFE44738} failed due to the following error:
80070424 The specified service does not exist as an installed service.
(Exception from HRESULT: 0x80070424). |
|
| Card 1451 View | 3D Modeling (AutoCAD Based) | Show System Model | None | Unhandled Exception | Raising to 3D and you get this error;
Exception Occured at AddURLToHyperlinks :: HydraHeads System.Runtime.InteropServices.COMException (0x80040154): Retrieving the COM class factory for component with CLSID {44D62FAE-67A7-4131-BF38-489CDFE44738} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)). |
|
| Card 1381 View | Standard (AutoCAD Based) | Grips | None | Slow | Customer reports that when trying to move an object by exposing the grips, the process takes a very long time and almost seems like AutoCAD freezes. "Clicking blocks and dragging by node, doing pipe sizings, etc..." |
|
| Card 1407 View | Plot (AutoCAD Based) | Plot | None | None | When plotting to Bluebeam document, some HydraCAD drawing entities show up blacked out. AutoCAD view; PDF generated by Bluebeam;
|
|
| Card 276 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | TOS block looks odd or has unusual insertion point or text is placed far away |
|
| Card 368 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | Check Elevation Command > after picking a point Internal error !dbobji.cpp@6861:eNotOpenForWrite and Autocad closes |
|
Page: