All Cards
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 816 View | HydraCALC (Revit Based) | Hydraulic Calculations | None | Error Placing Reference Points Or Demand Area Annotation.... | Error placing Reference Points or Demand Area annotation....
|
|
Card 815 View | HydraCALC (Standalone) | None | None | None | Column widths are randomly getting larger, enough so that many columns are too wide to be seen |
|
Card 814 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Using the crosshairs/pickbox to hover over an elevated HydraPIPE does not show the values for it. User cannot see the START Z, END Z or any other properties |
|
Card 812 View | HydraCALC (Standalone) | None | None | None | The copy/paste for HydraCALC and HydraLIST issues was a WebRoot issue |
|
Card 811 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Pipe Diameter does not get adjusted. New pipe not sized. |
|
Card 810 View | Couplings (AutoCAD Based) | Insert Couplings | None | Error: Bad Argument Type: Lentityp Nil | Error: bad argument type: lentityp nil |
|
Card 809 View | HydraLIST (Standalone) | Process | None | None | When I process a Stocklist the HVUF display doesn't look good. The printer displayed is not the one I want. |
|
Card 808 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Unhandled Exception | When trying to insert a newly defined Flexible Sprinkler Connection, an unhandled exception dialog box appears. |
|
Card 807 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Unhandled Exception | When trying to open the dialogue box to define a Flexible Sprinkler connection, the following message box error appears. Could not find file; FSC-INSERTDEFLINE.txt |
|
Card 806 View | HydraCALC (Revit Based) | None | None | Runtime Error | Calculation process stops at Step 1a.4, then runtime error 13, Type Mismatch |
|
Card 805 View | HydraLIST (Standalone) | Process | None | Runtime Error | Runtime Error 3167. Error message: Record has been deleted |
|
Card 804 View | HydraCALC (Standalone) | Insert Fittings | Name | File To Load Paths And Dirs. | After running an update to 50.54, user is getting this error when trying to add a fitting by right-clicking the fittings cell, a dialog box pops up saying, May happen with Pipe Schedule and adding a Pump as well. File to load paths and Dirs.(AND STRING CONVERSION) |
|
Card 803 View | 3D Modeling (AutoCAD Based) | Show System Model | None | Fatal Error | When attempting to 'Show Fittings' (SHF command), user gets an AutoCAD Fatal Error. Create 3D Model causes a fatal error
|
|
Card 802 View | All (Revit Based) | Open | None | External Tools - Duplicated Addinid | Failed to initialize the add-in "HydraTools" |
|
Card 801 View | HydraCAD (Revit Based) | Add Device | None | None | The Valve Selector is not displaying properly on 4K monitors (menu items and minimize/maximize/close buttons are not showing up, text and graphics are scaled incorrectly, general look and feel does not match the documentation, etc.). |
|
Card 800 View | All products (Security and Licensing) | None | None | Ff60 Or Ff3 Or Rh60 Or Rsn60 Or Rl60 | Hydratec Security Lock Error
For example: |
|
Card 798 View | HydraBID (Standalone) | Open | None | None | when picking New Take Off Sheet |
|
Card 797 View | HydraCALC (Revit Based) | Calculation Process | Continue | Unhandled Exception | When picking the continue button one gets an error message "Unhandled Exception... Item has already been added. Key in Dictionary. 'a number' Key being added: 'same number' |
|
Card 796 View | HydraCALC (Revit Based) | None | None | Bad Location Of K-Factor | Bad location of K-Factor |
|
Card 795 View | HydraCAD (Revit Based) | Spacing and Layout | Select | 0 |
|
Page: