All Cards
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 871 View | HydraLIST (Standalone) | Open | None | Security Lock Error 97 |
|
|
| Card 869 View | HydraCALC (Standalone) | Open | None | Runtime Error | When opening HydraCALC, a runtime-error 380 pops up. Invalid property value
|
|
| Card 868 View | HydraCALC (Standalone) | Open | None | Corrupt .Wxf | When opening a specific cac file you get this error
Other calc files open fine |
|
| Card 867 View | Add-Ins (Revit Based) | HydraCAD | Retrieve HydraCAD Revit MEP Content | System Exception | During the process to Retrieve HydraCAD Revit MEP Content, the following error occurs;
|
|
| Card 866 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Drawing Setup dialog doesn't load No error but when the HydraCAD template is selected, it goes straight to the drawing and command prompt, it doesn't ask for the user to set the scale factor
|
|
| Card 865 View | HydraLIST (Standalone) | Process | None | Hydralist Error 100 |
|
|
| Card 864 View | Launching HydraCAD (AutoCAD Based) | None | None | Unhandled Exception | When Opening HydraCAD or trying to list a drawing, you recieve any Error containing the following CLSID: 44D62FAE-67A7-4131-BF38-489CDFE44738
Or any of the following HRESULT error numbers: 0x800736B1
0x80040154
0x80070002
0x80080005
0x80029C4A TYPE_E_CANTLOADLIBRARY
|
|
| Card 863 View | HydraKEY (Security and Licensing) | None | Open | Failed Call To Server: Unable To Find An Entry Point Named 'Checkcodein' In Dll 'Hydexvb3.Dll'. |
|
|
| Card 862 View | HydraLIST (Revit Based) | Create Stocklist | Continue | Autolist – Error |
|
|
| Card 861 View | HydraCALC (Standalone) | Open | None | Loadregvalue For Strinstalldrive | When opening HydraCALC or trying to run a calculation, the dialog boxes below appear. "Loading from Master Data Location" "LoadRegValue for StrInstallDrive MasterLoad Form|Activaate = C:" After clicking OK or pressing ENTER, HydraCALC will open or finish up the calculation
|
|
| Card 860 View | HydraKEY (Security and Licensing) | None | Open | 102: Error Reading Entry Point |
|
|
| Card 859 View | Launching HydraCAD (AutoCAD Based) | None | None | Load Failed Ai_Utils.Lsp | Load failed AI_UTILS.LSP |
|
| Card 858 View | HydraCAD (Revit Based) | Spacing and Layout | New Head from Selector | Value Cannot Be Null | When selecting a new sprinkler from the Head Selector, after selecting Temp & Finish and upon pressing Select Head: Value cannot be null ...Parameter name: loadedFamily
|
|
| Card 857 View | HydraCAD (Revit Based) | Import Clashes | None | None | The function sort of worked but there were way more clashes in Navisworks than showed up in Revit. -or- Creating a .nwc file exports for Navisworks with "Convert Element ID's" box checked from Revit does not respect the ID in Revit proper. These element’s ID in Navisworks and Revit are different for the same element. |
|
| Card 856 View | HydraCALC Sizer (Standalone) | Open | None | Runtime Error | When trying to open HydraCALC Sizer, a 'run-time error 76', Path not found error pops up and the program doesn't open.
|
|
| Card 855 View | HydraCALC (Standalone) | Info Sheet | None | Runtime Error | When attempting to view the Info Sheet, the following error message pops up
|
|
| Card 854 View | Listing (AutoCAD Based) | Start Autolist | None | Hydracad Error | When starting the AutoLIST process, the message box shown below pops up. The process "pretends" to continue through, but when HydraLIST opens, it's completely blank.
Re-run Autolist with the drawing starting on the ground. Current run will not include any FSC information in the MISC tab in HydraList. |
|
| Card 853 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | The process to make the 3D model takes less than 1 millisecond and says it's successful, but after switching to the isometric view, no 3D pipes have been created.
ALSO SEE; |
|
| Card 852 View | HydraCAD (Revit Based) | Sleeves | Pick | None | No error ... Just no Sleeve |
|
| Card 850 View | HydraCALC (Standalone) | None | None | None | A grid system was processed from HydraCAD to HydraCALC but the calc file did not have L (left) and R (right) markers for autopeaking.
|
|