Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Piping (Ribbon/Toolbar/Location)

Button: Rapid Line Error Type: Fatal Error

Description:

When using Rapid Main or Rapid Line, clicking on the pipe causes a Fatal Error

Solutions:


1.
Cause:

User was using Rapid Line/Rapid Main/Rapid Pipe on pipe which had pretty pipes drawn on it and the SPRKVIEW layer was turned on.  The command finds the polyline/pline object instead of the line object and crashes out.

Solution:

Turn off the SPRKVIEW layer before using rapid pipes.


2.
Cause:

HydraCAD layers are locked

Solution:

Unlock the layers and run the command again.