All Cards
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 284 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Copy and Paste takes forever, slow process |
|
| Card 472 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | None | Unhandled exception has occurred in a component ... eBadLineTypeName The Pretty Pipe setup window will not open up. |
|
| Card 351 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Unable to select ceiling grid intersections when using Align Crosshairs with Ceiling |
|
| Card 649 View | HydraCALC (Standalone) | None | None | Final printout pages in HydraVIEW have data which looks smushed or overlapping or compressed or garbled or jumbled
|
||
| Card 392 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | No error message but cutting in couplings breaks the pipe but does not insert the couplings block. |
|
| Card 276 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | TOS block looks odd or has unusual insertion point or text is placed far away |
|
| Card 368 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | Check Elevation Command > after picking a point Internal error !dbobji.cpp@6861:eNotOpenForWrite and Autocad closes |
|
| Card 550 View | Collaborate (AutoCAD Based) | Revit Toolkit | Retrieve Content | None | Retrieve HydratecRevitContent is missing from the Add-Ins - Hydratec pulldown menu in Revit
|
|
| Card 572 View | HydraCALC (Standalone) | Open | None | Runtime 13 | When opening HydraCalc v50, you get Run-time error '13' Type mismatch OK The calc program MAY open but you cannot open any jobs or do anything in the window. |
|
| Card 573 View | HydraCALC (Standalone) | Utilities | Alter Pipe | None | Runtime 13 | Setting certain pipe diameters with specific pipe types gives an ID of 0. Eg. 1½" - SCHED 40 shows up as 0 rather than 1.61. n/a HydraCalc |
|
| Card 135 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | During the AutoCALC process, it gets hung up at step 5a.3b. Re-Ordering Pipe Paths - Phase 2
|
|
| Card 169 View | Listing (AutoCAD Based) | Start Autolist | None | Dao Error | While running AutoLIST, the process hangs when cleaning up lines database
DAO Server - Error RSEdit Call from 'AutoList :: CleanUpLinesDatabase (lineDB)'. DAO Error: No current record.
Then followed by the AutoLIST Failed! Please run Listing Checkups
|
|
| Card 267 View | 3D Modeling (AutoCAD Based) | Switch To Edit Mode | None | None | Vertical pipe issue. Switching back to Edit Mode (S2D) leaves HydraPipes in Hydrapipe layer. Then when trying to show system model again (S3D) you get an AutoCAD message box "Please Switch to Edit Mode" |
|
| Card 92 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Step 1a.3 - Fitting Exchange No replacement fitting name for 22E for Sched-10 Note: This could be any fitting or pipe type described in the error. If you click ok at each error, the process will run through without these fittings |
|
| Card 770 View | HydraLIST (Standalone) | Process | Print Reports | Freezes | HydraLIST process freezes at Processing Cover Page Report - Optimizing pipe Or freezes at processing pipe sketches Or at optimization
|
|
| Card 587 View | HydraCALC (Standalone) | Open | None | Runtime Error | When opening HydraCALC, you get the error "Invalid Property Value" Runtime 380 |
|
| Card 41 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Unkown (sic) Unknown fitting in drawing, cannot continue Type SME at the command line to open 'Show Model Errors' dialog box
|
|
| Card 48 View | HydraCALC (Standalone) | Calculate | None | Runtime Error | Runtime error 70 permission denied
|
|
| Card 457 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Bad update. These Files are missing system folder dependencies of HydexVB64 or HydexVB3: MFC100u.dll MSVCR100.dll MSVCP100.dll Because of this, no pass can be given nor does security work on any product. (64-bit products may work while 32-bit products don't or vice versa) Opening |
|
| Card 356 View | Launching HydraCAD (AutoCAD Based) | None | None | None | One or more toolbars cannot be found after selecting a menu or command. This happens because the toolbar is being opened 'off screen'. This usually happens when the computer has a dual monitor but the 2nd monitor isn't currently connected. |
|