AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist Error Type: Unhandled Exception

Description:

AutoCAD Error Aborting FATAL ERROR: Unhandled Access Violation Reading 0x00e0 Exception at [hex code here] Acad 2019 hex code; 2D92713Eh Fatal Error

 

 

Hex code a51b726eh

Solutions:

Cause:

Later updates of v53.05 & v54.02 & 56.01R1 had this problem arise if a 1" dry sidewall sprinkler or a 1" PLUG block was inserted on a 1" pipe in the SPRKDAT4 layer.

 

This forces a straight coupling on the end of an ARMOVER layer - SPRKDAT4 pipe.

Solution:

Until resolved - requires program change Delete the PLUG / use a CAP at the end of a pipe or Change the green pipe layer to yellow pipe.

[WHM 4/25/17 & GAB 6/11/18]

Updated: Nov. 20, 2023, 1:59 p.m. Created: March 1, 2019, midnight