Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
AutoCAD Based Listing (Ribbon/Toolbar/Location)
Description:

"AutoLIST Failed!... Please run Listing CheckUps"
This message is shown when running the AutoLIST process, but checkups didn't find any errors AutoLIST Failed
Outdated/unsigned application files
Using Windows File Explorer, navigate to this folder and check the version of this file by right-clicking it, selecting Properties, and check the DETAILS value tab.
C:\HES\Common
DAO32Server.exe
It should be file version 2025.10.20.32 or newer.
If you have an older version, please contact Hydratec for updates to these two files;
DAO32Server.exe
Dao32Server.tlb
1) Bad VP lengths in a Metric drawing
2) Grid has user defined RNs on both ends.
3) Fitting that does not exist. Ex. Head on a tee creating a 4 outlet fitting.
The length of the VP was 6mm and checkups didn't catch it as an error. A length of 6" is fine for Imperial, but in Metric, it's too small for AutoLIST to handle.
**IMPORTANT** If using HydraCAD 52.04 or older, you MUST close and re-open AutoCAD before running another AutoLIST as trying to run the process again will give a FATAL ERROR.
Bad install of HydraCAD, likely due to anti-virus blocking some HydraCAD install files [7/28/21 GAB]
User was running Kaspersky. Witnessed the install of HydraKEY, but then when we attempted to run it, Kaspersky blocked and DELETED the application. Disabling Kaspersky and re-installing HydraCAD fixed the issue.