Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 24 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | At end of AutoCalc steps, Path not Found, HydraCALC does not open |
|
Card 776 View | HydraLIST (Standalone) | Open | Opening | Runtime Error | Computer crashed unexpectedly while HydraLIST was open, then when attempting to re-open it, you get the error, Runtime Error 62, Input past end of file |
|
Card 872 View | HydraCALC (Standalone) | None | None | Runtime Error | When opening HydraCALC, user is greeted with Run-time error 62 Input past end of file
Runtime 62 Runtime Error 62 |
|
Card 607 View | HydraCALC (AutoCAD Based) | None | None | Runtime Error | While trying to open HydraCALC Sizer, user gets an error message saying; Run-time Error 62 Input past end of file Run Time Runtime Error 62 HydraCalc Sizer |
|
Card 1021 View | HydraCALC (Standalone) | Open | Double-Click | None | Double-clicking your HydraCALC icon makes nothing happen. You do not see HydraCALC open onscreen nor on your taskbar.
If you open your task manager and see the app "Hyd_prog.exe" open but not on your taskbar, then the application is stuck in purgatory. If you see entries here, use END TASK to get rid of them.
Another option may be that it's on the taskbar but not on your screen. That means it's open but offscreen. See this HydraCARD to fix that issue; HydraCARD 565 only AFTER you've checked on the solution below.
|
|
Card 1086 View | HydraCAD (Revit Based) | Hangers | None | None | Hangers dialog won't open: Unhandled exception has occurred... Object reference not set to an instance of an object |
|
Card 807 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Unhandled Exception | When trying to open the dialogue box to define a Flexible Sprinkler connection, the following message box error appears. Could not find file; FSC-INSERTDEFLINE.txt |
|
Card 781 View | Sprinklers (AutoCAD Based) | Select Sprinkler | Choose Part Number | Sprinkler Not Properly Configured | While using the 'Choose Part Number' button to open HydraHEAD Selector and retrieive its description and part number, you get the errors below; Runtime Error 713, Application-defined or object-defined error Sprinkler not properly configured. Please re-select using 'Choose part' |
|
Card 854 View | Listing (AutoCAD Based) | Start Autolist | None | Hydracad Error | When starting the AutoLIST process, the message box shown below pops up. The process "pretends" to continue through, but when HydraLIST opens, it's completely blank. |
|
Card 260 View | Launching HydraCAD (AutoCAD Based) | None | None | Security Error | When opening HydraCAD, you only receive this error message and not a HydraKEY error with the golden X. If you receive a HydraKEY error, search for the linked HydraCARD in that message box as it takes priority.
Security Error: One of the following conditions is likely; HydraCAD is unable to function under these conditions
After AutoCAD opens, press F2 to view the command prompt, see if the text below appears. If yes, see solution 1. Could not find file HCAD_ENV.INI Is 2024; error: no function definition: PRINTEM
|
|
Card 1099 View | HydraCAD (Revit Based) | Resize Diameters | None | Command Failure For External Command | Revit could not complete the external command... System.ArgumentException |
|
Card 1016 View | Collaborate (AutoCAD Based) | Navisworks Toolkit | None | None | After buiding your 3D risers, raising to 3D, exporting to a Persistent Model and Navisworks successfully, your 3D riser is missing, with the exception of the skipoles Your layers are on and the 3D_DETAIL layer is present, unlocked, thawed and visible, you just can't see the pipe and fittings. The one customer reporting this said they disappear if the drawing is closed then re-opened. They'll be visible in viewports as well, just not in 2D view.
See this related HydraCARD also; https://hydracards.hydratecinc.com/cards/card-1144
|
|
Card 1063 View | HydraCAD (Revit Based) | Add Device | None | Command Failure For External Command | Command failure for external command ... System.IO.FileNotFoundException ... File name 'AWSSDK' |
|
Card 629 View | HydraCALC (AutoCAD Based) | None | None | None | When opening HydraCALC, you get this error. Startup error An error has occured during startup. The decimal separator & digit grouping symbols are not set correctly in Control Panel! The digit grouping symbol must be a comma!
|
|
Card 907 View | Installation (AutoCAD Based) | None | None | Registry Problem | During the install of HydraCAD V56/57/58, the user is greeted with the message below. Following the both sets of instructions of opening and closing AutoCAD, and running a repair of AutoCAD do not make a difference. You'll still get the error message. V56 = R23.X V57 install will say; Neither AutoCAD 2021, 2022, 2023 nor 2024 found (missing registry key: HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R24.X). Please install it before re-running this install
|
|
Card 1188 View | Launching HydraCAD (AutoCAD Based) | Opening | None | Unhandled Exception | When opening HydraCAD you get the error;
Exception in hcadmainbase.arx ARX Command Unhandled Exception c0000027 (c0000027h) at address aca746e7h |
|
Card 1212 View | Ribbon Click (AutoCAD Based) | None | None | Fatal Error | Selecting any button from the AutoCAD ribbon creates the fatal error. Typing or using a toolbar does not create the error. AutoCAD Error Aborting FATAL ERROR: Unhandled e0434352h Exception at 6C6CCF19h Sometimes followed by; The program is missing Tool Palettes and Ribbons. |
|
Card 868 View | HydraCALC (Standalone) | Open | None | Corrupt .Wxf | When opening a specific cac file you get this error Other calc files open fine |
|
Card 728 View | HydraLIST (Standalone) | None | None | Runtime Error | Runtime Error 3159: not a valid bookmarkFile has input errors, user gets Runtime error 3159, HydraLIST closes and that file cannot be reopened. runtime error 3159
|
|
Card 1163 View | Listing (AutoCAD Based) | Listable Dynamic Block | None | Registry Problem | Trying to open Listable Dynamic Blocks and you get this error message
The problem is, you already have a newer version.
Go to HydraLIST, click [Help|About HydraLIST] to confirm. |