Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 838 View HydraLIST (Revit Based) Create Stocklist None Revit Could Not Complete The External Command.

Revit could not complete the external command     System.NullReferenceException

 

Card 1075 View HydraLIST (Revit Based) Tag Setup Ok None

ERROR: No fittings were found on the selected pipe

Card 1207 View HydraCAD (Revit Based) Tag Pipes None Command Failure For External Command

Command Failure for External Command... System.NullReferenceException

Card 1321 View Calculations (AutoCAD Based) Start Autocalcs None Hcad_Env.Ini Error

Keyboard alias "SAC"


After clicking OK in the AutoCalc Setup window and just before the process begins, you get the following error messages;


Problem updating your Hcad_env.ini file.  /n Will try to rebuild file. /r Pick OK then Restart AutoCALC

Your Hcad_env.ini file is possibly corrupted.  This calc will not continue

Card 1320 View Listing (AutoCAD Based) Start Autolist Hydralist Opens None

After running an Autolist, in HydraLIST and the LINES tab you have a listing tag ID called RM






Card 1312 View Template (AutoCAD Based) None None Unknown Command

No error occurs but HydraCAD will not properly load and Hcad commands do not work.  

A quick test is to select the drop menu [File|New], select the template file 'HydraCAD Imperial Default.dwt'.  

The Drawing Setup window should appear but it does not, it loads straight into a blank drawing.

This is what you should see (press F2 to review the text window);

      

 

Instead you only see;

HCAD_ADS r4 functions Loaded.

AutoCAD menu utilities loaded.
Requires an integer between 0 and 32767.

3dFitting registry keys found

Requires an integer between 0 and 32767. 
 

Card 1305 View Sprinklers (AutoCAD Based) FSC Setup None Message Box

When attempting to create a new FSC definition, you get this error message.  Clicking OK closes the command

 

Card 866 View Launching HydraCAD (AutoCAD Based) None None None

Drawing Setup dialog doesn't load

No error but when the HydraCAD template is selected, it goes straight to the drawing and command prompt, it doesn't ask for the user to set the scale factor

Card 1293 View HydraCAD (Revit Based) Spacing and Layout New Head From Selector None

Unhandled Exception... System.ArgumentOutOfRangeException: Index was out of range

Card 1304 View Sprinklers (AutoCAD Based) FSC Setup None Other

When inserting a flexible sprinkler connection (FSC) after its setup, you get two error messages

Error importing hose over size percent, check your FSC dialog properties

Setting Over Percent to 10%

Error importing hose under size percent, check your FSC dialog properties

Setting Under Percent to 20%

 

 

Clicking OK in each window will allow you to continue and insert the FSC detail

Card 878 View Sprinklers (AutoCAD Based) FSC Setup None Input String Was Not In A Correct Format

When defining a flexible sprinkler connection, the following error is raised ("Input string was not in a correct format"):

Card 1122 View Sprinklers (AutoCAD Based) FSC Insert None None

No error reported for FSC even when maximum length is clearly exceeded

 

If you view the FSC properties, it's possible the HoseLength and MaxNumberOfBends values are not set.

Card 807 View Sprinklers (AutoCAD Based) FSC Setup None Unhandled Exception

When trying to open the dialogue box to define a Flexible Sprinkler connection, the following message box error appears. 

Could not find file; FSC-INSERTDEFLINE.txt

Card 513 View Launching HydraCAD (AutoCAD Based) None None None

Install error.

Unknown Possible Win7 & InstallSheild conflict Setup Launcher Unicode Dialog Box InstallScript

Card 299 View Launching HydraCAD (AutoCAD Based) None None None

UCS is out of whack or the clockwise option is checked in units dialog Tagging

Card 965 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

Card 983 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

HydraCALC for Revit Setup...  Unhandled Exception

Card 1111 View HydraCALC (Revit Based) Hydraulic Calculations Load Defaults None

Unable to load defaults during HydraCALC Setup. Occasionally will give an error, but most commonly nothing will be filled in. 

Card 134 View Calculations (AutoCAD Based) Start Autocalcs Finish Area None

After 'finishing area' then exiting out of the Calc Setup screen, no HYD2 (white) reference points are inserted on the drawing Missing Reference Points No Reference Points

Card 547 View Launching HydraCAD (AutoCAD Based) None None None

Registry entries not getting setup correctly HES is not installed to the C:\ drive Missing the folder; C:\HES\HydraCAD\Ver50\common Partial uninstall of HydraCAD was done Dialog box Startup Acad 2019