Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
Revit Based HydraCAD (Ribbon/Toolbar/Location)
Description:
When trying to use Cleanup Tags, this error appears and nothing else happens (i.e. the tags were not cleaned up)


An issue with creating Clash Bubbles is causing the program to crash before it successfully completes the cleanup.
There are two solutions...


This will prevent the creation of clash bubbles. If you don't want to do that, refer to solution #2 (below)
An issue with creating Clash Bubbles is causing the program to crash before it successfully completes the cleanup.

Run a successful clash check to load the proper clash bubble family. Successful meaning this clash check must find an actual clash, in order to create / load the Clash Bubble family.