Your Quick Search:
"Supply Point"
Software:
Total results: 88 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
| Card 51 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Water supply test point not connected to a pipe. Reinsert water supply\test point |
|
| Card 1195 View | HydraCALC (Revit Based) | Supply Point | None | None | No error, but the section's background becomes blue / light blue after placing down the supply point
|
|
| Card 96 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Could not find fitting for water supply test point can not match |
|
| Card 17 View | HydraCAD (Revit Based) | Insert Pump | None | None | Pump is in water supply but no reference point PI |
|
| Card 85 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | When starting AutoCalc, the following error message appears: You have more than ONE Water Supply for these calculations... You have more then ONE Water Supply for these calculations... multiple source point |
|
| Card 1109 View | HydraCALC (Revit Based) | Supply Point | None | Command Failure For External Command | Revit could not complete the external command... No work plane set in current view
|
|
| Card 824 View | HydraCALC (Revit Based) | Supply Point | Pick | Revit Could Not Complete The External Command. | Command Failure for External Command.... Revit could not complete the external command.
|
|
| Card 926 View | HydraCALC (Standalone) | Calculate | Calculating | Message Box | Upon calculating a file, the error message, "Failed to launch C:\HES\Hydratec for revit\programs\calcdiagnose.exe" pops up.
Was preceeded by these messages;
Plus this; Number of Loops -1 and or Nodes with undesignated elevations
|
|
| Card 95 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | After raising to 3D, you see green lines extending from (0,0,0) to points on the drawing
You can erase the green lines and continue on, this is an annoyance and inconvenience but not really a problem. |
|
| Card 979 View | HydraCALC (Standalone) | Calculate | Calculation Results | System Is -Nan(Ind) Psi | After calculating the system, the results show, "Your System Has a Deficit" System is -nan(ind) psi over the Water Supply Curve
|
|
| Card 1061 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | Runtime Error |
Calculation stops at Step 1a.4 - calcing total lengths Can be accompanied with a "Runtime error 5 - invalid procedure call or argument" or "Runtime error 6 - overflow" |
|
| Card 1344 View | HydraCAD (Revit Based) | RTS Points | None | None | Pop-up immediately after selecting RTS Points
|
|
| Card 1403 View | HydraCALC (Revit Based) | All Ref Points | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 1402 View | HydraCAD (Revit Based) | Pretty Sprinklers | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 952 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | Missing Pipe | After running the AutoCALC process on a long grid system, you realize some of the gridlines in the middle didn't get picked up.
|
|
| Card 121 View | Calculations (AutoCAD Based) | Start Autocalcs | None | 0 | When starting the AutoCALC process, you get this error;
Could not find fitting match for Pump Only/Test Point Please check!! You also see an Accessing Database window with a partial green progress bar. No Operating Heads of Flows Found!! Please check...
|
|
| Card 1376 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | Error placing Reference Points or Demand Area annotation... The 3D view ownerDBViewId is not locked. |
|
| Card 1371 View | HydraCAD (Revit Based) | Connect Pipes | Raise Pipe | Command Failure For External Command | Revit could not complete the external command... Curve length is too small for Revit's tolerance
|
|
| Card 11 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | 1a.1 | Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2
can also be Step 1a.4 |
|
| Card 1077 View | HydraCALC (Standalone) | Print Final | Results | Discrepancy | Reviewing the results you notice a discrepancy between the k-factor of an equivalent k versus a sprinkler head using that equivalent k-factor
In the example below, EQ02 has a k-factor of 5.37. Reference point 1 is supposed to use the k-factor of EQ02 (5.37) but in fact is using a different value (5.36).
|
|
Page: