Your Quick Search:
"Delete Primary Tags"
Software:
Total results: 37 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 946 View | Listing (AutoCAD Based) | Start Autolist | None | None | When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing. It only shows the original tag of MAIN A Same can be said for line tags #LN1.1, #LN1.2, etc |
|
Card 1156 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the external command... Autodesk.Revit.Exceptions.InvalidObjectException |
|
Card 1155 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the external command... x must be a finite number |
|
Card 1141 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the External Command... System.NullReferenceException |
|
Card 805 View | HydraLIST (Standalone) | Process | None | Runtime Error | Runtime Error 3167. Error message: Record has been deleted |
|
Card 699 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Untitled.hlf is somehow protected and will not delete. Runtime Error 70, 70 |
|
Card 838 View | HydraLIST (Revit Based) | Create Stocklist | None | Revit Could Not Complete The External Command. | Revit could not complete the external command System.NullReferenceException |
|
Card 15 View | HydraCAD (Revit Based) | None | None | None | Error Message - The duct/pipe has been modified to be in the opposite direction causing the connections to be invalid. The referenced object is not valid, possibly because it has been deleted from the database, or its creation was undone. |
|
Card 906 View | HydraCAD (Revit Based) | Pretty Sprinklers | None | None | The following sprinkler tags are not loaded ... |
|
Card 692 View | HydraLIST (Standalone) | None | None | None | The install path in the registry is incorrect. The user changed the Master Data location to the server, then changed it back to the C:\ drive and forced the data load, causing the files in the setup folder to be deleted as hydralist opened. In one case, copying over MASK.MDB didn't help, as a Runtime Error 70 (Permission Denied) was displayed, and MASK.MDB was gone from the folder. Runtime Error 53 |
|
Card 1042 View | HydraCAD (Revit Based) | Insert Pump | None | Command Failure For External Command | Command Failure for External Command... ...System.IO.DirectoryNotFoundException |
|
Card 1060 View | HydraKEY (Security and Licensing) | Installation | None | None | HydraKEY icon disappears from the desktop when trying to run the application after install. |
|
Card 737 View | HydraLIST (Standalone) | Process | None | None | Avast Anti Virus software with sandbox is installed on the computer the Anti Virus thinks the process program has been selected as a possible virus file. The program runs in the sandbox the process files are stored in the sandbox and then when the process is completed the sandbox is delete along with everything that happed while in the sandbox none |
|
Card 1098 View | HydraCAD (Revit Based) | Spacing and Layout | None | Command Failure For External Command | When trying to run Spacing and Layout, this error appears. Revit could not complete the external command... System.NullReferenceException Also could encounter this error: |
|
Card 38 View | HydraCAD (Revit Based) | Spacing and Layout | Opening | Autodesk.Revit.Exceptions.Invalidobjectexception | Using the Sprinkler Spacing and Layout tool: Revit encountered a Autodesk.Revit.Exceptions.InvalidObjectException: The referenced object is not valid, possibly because it has been deleted from the database, or it's creation was undone. |
|
Card 1095 View | HydraCAD (Revit Based) | Configure Head | Connect To Outlet | None | When using the Continuous option, after I am done I get an error and all the changes are erased. |
|
Card 702 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Some application unistalled or delete miscrosfot jet files form the computer. Most if not all of the files listed below are missing from either the windows/system32 folder or the program file/common/miscrosoft shared/dao folder DAO350.dll ExpSrv.dll MSJet35.dll MSJInt35.dll MSJtEr35.dll MSRepl35.dll MSRD2x35.dll MSVCRT40.dll VB5DB.dll VBAJet32.dll Runtime error 3633, 3633 |