Your Quick Search:
"couplings"
Software:
Total results: 23 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 1050 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | Couplings get closer than expected to outlets when cutting in. |
|
Card 944 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | No Error, the couplings simply display way too big! They show as huge couplings in coarse detail and medium detail. |
|
Card 881 View | File (Revit Based) | None | Coupling do not show, display, print, plot and are not visible in any fashion in plot views with display detail set to coarse or medium. Was reported by Davis as : the couplings on long runs of pipe don’t show up in our plot views. No matter if we use medium or course detail level. |
|||
Card 168 View | Listing (AutoCAD Based) | Start Autolist | None | None | HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method |
|
Card 1154 View | HydraLIST (Revit Based) | Auto Stocklist | None | None | When the stocklist is finished, it shows the main as one long & continuous pipe, and not segmented by couplings, etc. Main A is too long. |
|
Card 1139 View | Couplings (AutoCAD Based) | Custom Coupling | None | None | When running the Custom Coupling command [CC], the tooltip which follows the crosshairs duplicates the Command Line text, it does not show the drag distance and angle from the origin
The tooltip would be more useful if it showed the distance from the start point
|
|
Card 1165 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | When running the Line Couplings command (LC), you get the error, "No branch lines found crossing the line(s) you picked", even though it's 100% a fact the lines are intersecting
|
|
Card 1076 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | No error, but when trying to use Add Couplings, Revit stops responding and the couplings are never placed. |
|
Card 1144 View | Build 3D Risers (AutoCAD Based) | None | None | None | 3D Details (3D Fittings) missing, only the skipoles are showing |
|
Card 977 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | No error, but couplings do not show up in the project in Medium or Coarse detail. |
|
Card 302 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Cannot insert pipe diameters or cut in couplings that also insert pipe diameters. |
|
Card 1038 View | HydraCAD (Revit Based) | Configure Head | Change Configuration | Command Failure For External Command | Command Failure for External Command... ....System.Exception: No routing preference set for... |
|
Card 1065 View | HydraCAD (Revit Based) | Couplings | Add Couplings | Command Failure For External Command | Command Failure for External Command... System.OutOfMemoryException |
|
Card 1064 View | HydraCAD (Revit Based) | Couplings | Add Couplings | Command Failure For External Command | Command Failure for External Command... System.NullReferenceException |
|
Card 474 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | The diameter tag HANDLE is 0000 this number is used to determin if the pipe is sloped - yielding an incorrect pipe length. Move Line / Move Main make the diameter tag HANDLE be 0000 |
|
Card 392 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Drawing is saved on a server or the cloud. |
|
Card 372 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Program has become "tired" |
|
Card 811 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Pipe Diameter does not get adjusted. New pipe not sized. |
|
Card 249 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Interestingly PDMODE is set to 1. This means that there is no node point at the insertion of these sizes, so the sizes are not found. |
|
Card 810 View | Couplings (AutoCAD Based) | Insert Couplings | None | Error: Bad Argument Type: Lentityp Nil | Error: bad argument type: lentityp nil |
Page: