Advanced Search
Total results: 14
Page:
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
Card 1144 View | Build 3D Risers (AutoCAD Based) | None | None | None | 3D Details (3D Fittings) missing, only the skipoles are showing |
|
Card 1139 View | Couplings (AutoCAD Based) | Custom Coupling | None | None | When running the Custom Coupling command [CC], the tooltip which follows the crosshairs duplicates the Command Line text, it does not show the drag distance and angle from the origin
The tooltip would be more useful if it showed the distance from the start point
|
|
Card 302 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Cannot insert pipe diameters or cut in couplings that also insert pipe diameters. |
|
Card 168 View | Listing (AutoCAD Based) | Start Autolist | None | None | HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method |
|
Card 1218 View | HydraCAD (Revit Based) | None | None | None | No error, but the rounding of the loose fitting and coupling schedule's rounding is behaving incorrectly to what's desired, for example, rounding 1-1/2” to 2”. |
|
Card 1165 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | When running the Line Couplings command (LC), you get the error, "No branch lines found crossing the line(s) you picked", even though it's 100% a fact the lines are intersecting
|
|
Card 885 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Runtime Error 6 when Attaching Fittings Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2. Trying to run a auto calc from a drawing. How do I find the referenced pipes? |
|
Card 1154 View | HydraLIST (Revit Based) | Auto Stocklist | None | None | When the stocklist is finished, it shows the main as one long & continuous pipe, and not segmented by couplings, etc. Main A is too long. |
|
Card 1050 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | Couplings get closer than expected to outlets when cutting in. |
|
Card 881 View | File (Revit Based) | None | Coupling do not show, display, print, plot and are not visible in any fashion in plot views with display detail set to coarse or medium. Was reported by Davis as : the couplings on long runs of pipe don’t show up in our plot views. No matter if we use medium or course detail level. |
Page: