Revit Based HydraCAD (Ribbon/Toolbar/Location)
Description:
No error, but when trying to use Add Couplings, Revit stops responding and the couplings are never placed.
An update was made to the Couplings tool that treats the value of the Maximum Distance from Existing Fittings as a length in Feet' - Inches", where it had previously only wanted a number in Inches.
The Couplings program remembers the previous value, and tries to cut in couplings 6 feet apart, as an example, and doesn't actually freeze but takes a very long time to eventually give an error.
Reenter your spacing as a length in Feet' - Inches", a typical spacing being 0' - 6", the minimum recommended length being 0' - 2", and the maximum being 1' - 0"