AutoCAD Based Couplings (Ribbon/Toolbar/Location)

Button: Insert Couplings Error Type: Error: bad argument type: lentityp nil

Description:

Error: bad argument type: lentityp nil

Solutions:


1.
Cause:

Pipe Diamter blocks have a Z coordinate

Solution:

1. Select one pipe dim block then right-click and use Select Similar to select all the PIPEX blocks on your drawing. 

 

2. Then go to PROPERTIES and set Position Z to be 0 (zero).  Press ENTER when done.

 

 

 


2.
Cause:

Pipe Diamter blocks have a Z coordinate

Solution:

*This is an older option which has limited success - GAB

Run Eliminate Z-Coords Phase 2 (Or type in ZERO2)