* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 1391 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Unhandled Exception | When performing AutoCalc, the following error is displayed. |
|
Card 1144 View | Build 3D Risers (AutoCAD Based) | None | None | None | 3D Details (3D Fittings) missing, only the skipoles are showing |
|
Card 1099 View | HydraCAD (Revit Based) | Resize Diameters | None | Command Failure For External Command | Revit could not complete the external command... System.ArgumentException |
|
Card 1305 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Message Box | When attempting to create a new FSC definition, you get this error message. Clicking OK closes the command
|
|
Card 1293 View | HydraCAD (Revit Based) | Spacing and Layout | New Head From Selector | None | Unhandled Exception... System.ArgumentOutOfRangeException: Index was out of range |
|
Card 1022 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Error During Load | When starting the process to insert a Flexible Sprinkler Connection, you get the error message above; An error occurred reading the FSC-Selections.txt
|
|
Card 807 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Unhandled Exception | When trying to open the dialogue box to define a Flexible Sprinkler connection, the following message box error appears. Could not find file; FSC-INSERTDEFLINE.txt |
|
Card 816 View | HydraCALC (Revit Based) | Hydraulic Calculations | None | Error Placing Reference Points Or Demand Area Annotation.... | Error placing Reference Points or Demand Area annotation....
|
|
Card 25 View | HydraCALC (Revit Based) | Hydraulic Calculations | Return To Revit | None | Error placing reference points or demand area annotation...... System.IndexOutOfRangeException: Index was outside the bounds of the array "Make Pipe Type Info Array String" |
|
Card 1139 View | Couplings (AutoCAD Based) | Custom Coupling | None | None | When running the Custom Coupling command [CC], the tooltip which follows the crosshairs duplicates the Command Line text, it does not show the drag distance and angle from the origin
The tooltip would be more useful if it showed the distance from the start point
|
|
Card 165 View | Listing (AutoCAD Based) | Start Autolist | None | Dao Error | Call from AutoList::AddLineItemsToDatabase DAO Error changes requested to table not successful - create duplicate values in the index, primary key.... The line it failed to write is logged in C:\HES\TEMP\DAOUpdateError.txt Also: DAO Server Error RSU Update Call from Autolist DAO Error |
|
Card 302 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Cannot insert pipe diameters or cut in couplings that also insert pipe diameters. |
|
Card 168 View | Listing (AutoCAD Based) | Start Autolist | None | None | HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method |
|
Card 527 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | Unhandled Exception | Unhandled Exception has occurred in a component in your application |
|
Card 109 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Unhandled Exception | Unhandled exception has occurred in a component in your application Index was outside the boundary of the array *APPLIES TO:* v52.05 r2, September 16 & 17 update only |
|
Card 1218 View | HydraCAD (Revit Based) | None | None | None | No error, but the rounding of the loose fitting and coupling schedule's rounding is behaving incorrectly to what's desired, for example, rounding 1-1/2” to 2”. |
|
Card 1165 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | When running the Line Couplings command (LC), you get the error, "No branch lines found crossing the line(s) you picked", even though it's 100% a fact the lines are intersecting
|
|
Card 418 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via Parts Tree | None | Unhandled Exception | When trying to insert a 3D fitting via the Fittings Parts Tree, the user gets the error message; Microsoft .NET Framework When user clicks CONTINUE and tries to use the INSERT button to insert a fitting, another dialog box pops up INSERT FITTINGS |
|
Card 885 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Runtime Error 6 when Attaching Fittings Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2. Trying to run a auto calc from a drawing. How do I find the referenced pipes? |
|