Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 1062 View Display (AutoCAD Based) Osnaps None Other

When drawing objects, you get these icons/images/boxes next to the drawn object.  If you hover over it, it mentions an osnap option

Card 1319 View HydraKEY (Security and Licensing) Opening Subscription Activation Activation Failure

Subscription cannot be activated at this time.

Card 11 View HydraCALC (Revit Based) Hydraulic Calculations Continue 1a.1

Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2

can also be Step 1a.4

Card 1359 View Add-Ins (Revit Based) HydraCAD Retrieve Hydracad Revit Mep Content Command Failure For External Command

Revit could not complete the external command... Revit encountered a Attempt to modify the model outside of transaction


Card 1358 View 3D Modeling (AutoCAD Based) S3D - Raise to 3D None None

When closing a drawing in 3D, and later re-opening and returning to 2D, some of the drawing symbols show up looking like outlines (Hangers, Sprinklers, etc)


Card 987 View Launching HydraCAD (AutoCAD Based) None None None

When opening HydraCAD, you get the error message saying, "The Ribbon does not have any tabs or panels currently loaded"

Card 1357 View Launching HydraCAD (AutoCAD Based) None None None

HydraCAD Critical Error... Visual Lisp not available


Card 1356 View HydraCAD (Revit Based) Hangers None None

Error appears when opening Hangers

Failed to load the following families: z_Pipe Elevation Marker


Card 718 View HydraLIST (Standalone) Test Point None Runtime Error

Run-time error 3051... The Microsoft Jet database engine cannot open the file

Can happen when opening HydraLIST or Head Selector

50.00.14+

Card 346 View Collaborate (AutoCAD Based) Navisworks Toolkit Import Clashes None

1. Import clash errors does not work. Display Units any

Card 884 View Launching HydraCAD (AutoCAD Based) Install None Bad Argument Type: Numberp: Nil

bad argument type: numberp: nil

Card 1355 View All (Revit Based) Setup None None

Revit could not complete the external command... Missing file


Card 1354 View HydraTools (AutoCAD Based) Fluid Delivery Time (FDT) None None

Runtime Error 5 running FDT command on Metric drawing


Card 1144 View Build 3D Risers (AutoCAD Based) None None None

3D Details (3D Fittings) missing, only the skipoles are showing

Card 1353 View Sprinklers (AutoCAD Based) Select Sprinkler Head Selector None

Blacked out cells in Head Selector dialog


Card 912 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Unhandled Exception has occurred in a component in your application.

One of the identified items was in an invalid format



Card 1351 View Display (AutoCAD Based) None None None

 No inch marks (“) after the pipe diameter or there are but you prefer to remove them



Card 1077 View HydraCALC (Standalone) Print Final Results Discrepancy

Reviewing the results you notice a discrepancy between the k-factor of an equivalent k versus a sprinkler head using that equivalent k-factor

 

In the example below, EQ02 has a k-factor of 5.37.  Reference point 1 is supposed to use the k-factor of EQ02 (5.37) but in fact is using a different value (5.36).

 

Card 1061 View HydraCALC (Revit Based) Hydraulic Calculations Continue Runtime Error

Calculation stops at Step 1a.4 - calcing total lengths

There is also Runtime error 5 invalid procedure call or argument 

Card 1235 View HydraKEY (Security and Licensing) Using None None

Server Subscription Error when getting available subscriptions.