AutoCAD Based Collaborate (Ribbon/Toolbar/Location)

Button: Navisworks Toolkit Function: Import Clashes

Description:

1. Import clash errors does not work. Display Units any

Solutions:

Cause:

1. Import clash errors does not work.

Solution:

1a. Check that Navisworks UNITS equals the units of the drawing you are working on. Navisworks ships as default Metric - Meters it needs to be set to Feet Inches Fractions for Imperial/English. 1b. When running clash detection, Sprinklers must come first - i.e the clash report must be Sprinklers vs. Electric, it cannot be Electric vs. Sprinklers. Clash report file name must be HCAD_CLASH_DATA.txt, after running and saving the report, it must be located in the C:\HES\Temp folder.

Updated: Feb. 19, 2024, 1:16 p.m. Created: March 1, 2019, midnight