Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 97 View Calculations (AutoCAD Based) Reference Points None None

1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location

2. New ref points in HydraCALC are not using the values of the HYD ref points.

Card 1403 View HydraCALC (Revit Based) All Ref Points None None

When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. 
When trying to get them back by re-running 
All Ref Points, they don't reappear.

Card 840 View Calculations (AutoCAD Based) Start Autocalcs Finish Area None

AutoCALC is creating extra node points where there shouldn't be.  In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.

 

'extra node'

'extra ref point'

'extra reference point'

'refpt'

Card 1402 View HydraCAD (Revit Based) Pretty Sprinklers None None

When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. 
When trying to get them back by re-running 
All Ref Points, they don't reappear.

Card 1376 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

Error placing Reference Points or Demand Area annotation... The 3D view ownerDBViewId is not locked.

Card 11 View HydraCALC (Revit Based) Hydraulic Calculations Continue 1a.1

Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2

can also be Step 1a.4

Card 391 View Calculations (AutoCAD Based) Dummy Reference Points None None

Dummy reference points cannot find the dummy ref point block in the drawing's block table. **Possible there's a missing registry entry** Dialog box 52.04

Card 70 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Duplicated Hydraulic Ref Point

 

Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID

Duplicated hydraulic ref points

 

 

Card 526 View Calculations (AutoCAD Based) Reference Points None None

Bad ref point block Dialog box

Card 1457 View HydraCALC (Revit Based) All Ref Points None System.Nullreferenceexception:

When trying to add reference points, none are added and this error shows:


Card 1422 View HydraCALC (Revit Based) All Ref Points None System.Nullreferenceexception:

When trying to add reference points, none are added and this error shows:


Card 1478 View View (Revit Based) Floor Plan None None

Pipe fittings in certain views were grayed out and could not be selected, making it impossible to edit or work with them.

Card 1469 View Piping (AutoCAD Based) Define Pipe Elevations None Unhandled Exception

Error occurs when using some commands.

Autodesk has just released AutoCAD 2026.1.2 - and it breaks HydraCAD. It includes a major programming change by Autodesk that will require a lot of work and a large update by us. That update is being worked on right now, along with a version of HydraCAD for AutoCAD 2027. Both are now affected by essentially the same programming change.


BinaryFormatter serialization and deserialization are disabled within this application. See  https://aka.ms/binaryformatter for more information.


Other commands with this error;

Sprinkler Layout dialog (SL command)

Card 1476 View Installation (AutoCAD Based) None None None

During the HydraCAD install, you get an error saying, "InstallShield Wizard - Unable to find HKEY_CLASSES_ROOT\.DWG registry key.  You may need to repair AutoCAD or reinstall it



Card 463 View Launching HydraCAD (AutoCAD Based) None None None

1. Missing profile 2. Bad registry entry 3. User does not have Admin privileges Unable to find profile Installation Acad 2015~

Card 907 View Installation (AutoCAD Based) None None Registry Problem

During the install of HydraCAD V56/57/58, the user is greeted with the message below.  Following the both sets of instructions of opening and closing AutoCAD, and running a repair of AutoCAD do not make a difference.  You'll still get the error message.

V56 = R23.X
V57 = R24.X
V58 = R25.X

V57 install will say;

Neither AutoCAD 2021, 2022, 2023 nor 2024 found (missing registry key:

HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R24.X).

Please install it before re-running this install

 

 

Card 260 View Launching HydraCAD (AutoCAD Based) None None Security Error

When opening HydraCAD, you only receive this error message and not a HydraKEY error with the golden X.  If you receive a HydraKEY error, search for the linked HydraCARD in that message box as it takes priority.

 

Security Error: One of the following conditions is possible

HydraCAD is unable to function under these conditions.

  • Lock database needs updating in HydraKEY
  • Accounting flag on your account
  • Hardware lock not plugged in
  • Extra ACAD.RX file found in folder in Support File Search Path
  • Sentinel driver is missing
  • InstallPath registry item set to wrong drive

After AutoCAD opens, press F2 to view the command prompt, see if the text below appears.  If yes, see solution 1.

Could not find file HCAD_ENV.INI

Is 2024; error: no function definition: PRINTEM

 

Card 389 View 3D Modeling (AutoCAD Based) Show System Model None None

Upon starting the Show 3D command (S3D) the drawing immediately switches to SE isometric, reports no errors but no 3D piping is visible.  Even newly drawn pipe won't elevate.

Drawing successfully elevated to 3D. No errors were found

Related HydraCARD: #853

https://hydracards.hydratecinc.com/cards/card-853

Card 165 View Listing (AutoCAD Based) Start Autolist None Dao Error

Call from AutoList::AddLineItemsToDatabase DAO Error changes requested to table not successful - create duplicate values in the index, primary key.... The line it failed to write is logged in C:\HES\TEMP\DAOUpdateError.txt Also: DAO Server Error RSU Update Call from Autolist DAO Error

Card 13 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

Step 1a.1 - Error Box - User ID Duplicated

Transfer to HydraCalc - Step I1a.10 System is now 'Attaching Node 2 Elevations error occurs, please report both the step number and the step description to support! Error Display Error Type User ID Duplicated Step Ref 1 Ref 2 Ref 3 I Ref 4 1a.1