Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 97 View | Calculations (AutoCAD Based) | Reference Points | None | None | 1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location 2. New ref points in HydraCALC are not using the values of the HYD ref points. |
|
Card 840 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | AutoCALC is creating extra node points where there shouldn't be. In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.
'extra node' 'extra ref point' 'extra reference point' 'refpt' |
|
Card 11 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | 1a.1 | Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2 can also be Step 1a.4 |
|
Card 391 View | Calculations (AutoCAD Based) | Dummy Reference Points | None | None | Dummy reference points cannot find the dummy ref point block in the drawing's block table. **Possible there's a missing registry entry** Dialog box 52.04 |
|
Card 70 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Duplicated Hydraulic Ref Point |
Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID Duplicated hydraulic ref points
|
|
Card 526 View | Calculations (AutoCAD Based) | Reference Points | None | None | Bad ref point block Dialog box |
|
Card 1371 View | HydraCAD (Revit Based) | Connect Pipes | Raise Pipe | Command Failure For External Command | Revit could not complete the external command... Curve length is too small for Revit's tolerance |
|
Card 1086 View | HydraCAD (Revit Based) | Hangers | None | None | Hangers dialog won't open: Unhandled exception has occurred... Object reference not set to an instance of an object |
|
Card 356 View | Launching HydraCAD (AutoCAD Based) | None | None | None | One or more toolbars cannot be found after selecting a menu or command. This happens because the toolbar is being opened 'off screen'. This usually happens when the computer has a dual monitor but the 2nd monitor isn't currently connected. |
|
Card 562 View | HydraCALC (AutoCAD Based) | Print Final | None | Runtime Error | Printing a calc shows this error in HydraVIEW; File not found Runtime Error 53 |
|
Card 1364 View | Build 3D Risers (AutoCAD Based) | Viewport | None | Other | While in your viewport, your riser is visible while in the 2D Wireframe view. However if you change the Visual Style to Conceptual or Shades of Grey/Shades of Gray, your 3D riser disappears. You may notice if re-appears if you zoom out. |
|
Card 708 View | HydraLIST (Standalone) | Process | None | None | 1)This error usually means that the user does not have full access for the folder. Or a lock file already exists and can not be delete. 2) real time virus scan blocking file. 3050 |
|
Card 716 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Run-time Error 339 "Component tab32x30.OCX, spr32x25.OCX, spr32x35.OCX (or a different .OCX file) or one of its dependencies not correctly registered" "A file is missing or invalid"
|
|
Card 1319 View | HydraKEY (Security and Licensing) | Opening | Subscription Activation | Activation Failure | Subscription cannot be activated at this time. |
|
Card 1360 View | Installation (AutoCAD Based) | None | None | None | During the install of HydraCAD, you get an error, "Setup Needs the Next Disk, Please insert disk 1 that contains the file data2cab" |
|
Card 1351 View | Display (AutoCAD Based) | None | None | None | No inch marks (“) after the pipe diameter or there are but you prefer to remove them |
|
Card 1077 View | HydraCALC (Standalone) | Print Final | Results | Discrepancy | Reviewing the results you notice a discrepancy between the k-factor of an equivalent k versus a sprinkler head using that equivalent k-factor
In the example below, EQ02 has a k-factor of 5.37. Reference point 1 is supposed to use the k-factor of EQ02 (5.37) but in fact is using a different value (5.36).
|
|
Card 1061 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | Runtime Error | Calculation stops at Step 1a.4 - calcing total lengths There is also Runtime error 5 invalid procedure call or argument |
|
Card 461 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Inserting a pipe dimension (pipex) places it at the end of the pipe, including its center grip or not even on the pipe at all See solution #3 if the PIPEX is not on the pipe |
|
Card 1350 View | Opening a Drawing (AutoCAD Based) | None | None | None | After opening AutoCAD and a drawing, you have a dead area where you can't draw nor does anything display. Usually next to a compressed palette. Note in the image below how the crosshairs do not extend to this area. |