Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 946 View Listing (AutoCAD Based) Start Autolist None None

When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing.  It only shows the original tag of MAIN A 

Same can be said for line tags #LN1.1, #LN1.2, etc

Card 1410 View Piping (AutoCAD Based) Size Pipe Setup None None

When attempting to insert a pipe dimension you get the error "Invalid option keyword"



And the command prompt says "Enter an UNDO control option" with the dialog showing your choices

Card 1372 View Opening a Drawing (AutoCAD Based) None None None

When opening AutoCAD, you get an error saying "a software problem has AutoCAD to close unexpectedly"

Upon reviewing the file it's crashed on, it shows HCAD_MAKEFIGHANGERLIST as the culprit


Card 979 View HydraCALC (Standalone) Calculate Calculation Results System Is -Nan(Ind) Psi

After calculating the system, the results show, "Your System Has a Deficit"

System is -nan(ind) psi over the Water Supply Curve

Card 1407 View Plot (AutoCAD Based) Plot None None

When plotting to Bluebeam document, some HydraCAD drawing entities show up blacked out.

AutoCAD view;


PDF generated by Bluebeam;


Card 1091 View Installation (Revit Based) None None None

Greyed out options in the Addin Assistant and ribbons do not appear in Revit

Card 854 View Listing (AutoCAD Based) Start Autolist None Hydracad Error

When starting the AutoLIST process, the message box shown below pops up.  The process "pretends" to continue through, but when HydraLIST opens, it's completely blank.


Re-run Autolist with the drawing starting on the ground. Current run will not include any FSC information in the MISC tab in HydraList.

Card 922 View HydraCALC (Standalone) Info Sheet Print None

When viewing the final calc printout, the info sheet shows the line,

text1(35) - invisible

Card 573 View HydraCALC (Standalone) Utilities | Alter Pipe None Runtime 13

Setting certain pipe diameters with specific pipe types gives an ID of 0.

Eg. 1½" - SCHED 40 shows up as 0 rather than 1.61. n/a HydraCalc

Card 41 View Calculations (AutoCAD Based) Start Autocalcs None None

Unknown fitting in drawing, cannot continue

Type SME at the command line to open 'Show Model Errors' dialog box



Card 141 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Message Box

System seems to hang at this step, but eventually shows the error;

Hydraulic Calculation - The system flow demand of ####.## exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO.

 

The calculation will not continue Calculation failed for an unknown reason

May not be 1a.3 or 2.3, could be anywhere along here.

Card 1346 View Display (AutoCAD Based) None None None

 Line / Main tags are blocking items behind the text / tags are not transparent


Card 1396 View Listing (AutoCAD Based) New Tag None Invalid Color Number

When inserting a listing tag on a pipe, you get the error, "Invalid color number"


Card 1393 View Sprinklers (AutoCAD Based) FSC Setup None None

When running the "FSC Setup" to "Create FSC Definition". 
Upon finishing the block definition, the block definition is missing a crucial property for "Hydraulic equivalent length is referenced by:". This field will show blank or the default generic text and did not include the HydraCALC pipe/fitting reference information.

There is a missing HydraCALC "ImportExport" directory.

Default line text:
`Hydraulic equivalent length is referenced by: shortname with length number - longname Listing: FM`


Card 474 View Couplings (AutoCAD Based) Insert Couplings None None

The diameter tag HANDLE is 0000 this number is used to determin if the pipe is sloped - yielding an incorrect pipe length. Move Line / Move Main make the diameter tag HANDLE be 0000

Card 1377 View HydraCAD (Revit Based) Tag Pipes None Command Failure For External Command

Revit could not complete the external command... The 3D view ownerDBViewId is not locked


Card 562 View HydraCALC (AutoCAD Based) Print Final None Runtime Error

Printing a calc shows this error in HydraVIEW;

File not found Runtime Error 53


Card 1365 View HydraCAD (Revit Based) Hangers Dialog Box Missing Detail

When selecting Adjustable Ring Hangers for pipe sizes larger than 8" the detail does not show.

Card 1358 View 3D Modeling (AutoCAD Based) S3D - Raise to 3D None None

When closing a drawing in 3D, and later re-opening and returning to 2D, some of the drawing symbols show up looking like outlines (Hangers, Sprinklers, etc)


Card 1144 View Build 3D Risers (AutoCAD Based) None None None

3D Details (3D Fittings) missing, only the skipoles are showing