Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 946 View | Listing (AutoCAD Based) | Start Autolist | None | None | When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing. It only shows the original tag of MAIN A Same can be said for line tags #LN1.1, #LN1.2, etc |
|
Card 562 View | HydraCALC (AutoCAD Based) | Print Final | None | Runtime Error | Printing a calc shows this error in HydraVIEW; File not found Runtime Error 53 |
|
Card 1365 View | HydraCAD (Revit Based) | Hangers | Dialog Box | Missing Detail | When selecting Adjustable Ring Hangers for pipe sizes larger than 8" the detail does not show. |
|
Card 1358 View | 3D Modeling (AutoCAD Based) | S3D - Raise to 3D | None | None | When closing a drawing in 3D, and later re-opening and returning to 2D, some of the drawing symbols show up looking like outlines (Hangers, Sprinklers, etc) |
|
Card 1144 View | Build 3D Risers (AutoCAD Based) | None | None | None | 3D Details (3D Fittings) missing, only the skipoles are showing |
|
Card 1346 View | Display (AutoCAD Based) | None | None | None | Line / Main tags are blocking items behind the text / tags are not transparent |
|
Card 1168 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | Calc stops at Step 2.3 (Can also show Run-time error 62) |
|
Card 854 View | Listing (AutoCAD Based) | Start Autolist | None | Hydracad Error | When starting the AutoLIST process, the message box shown below pops up. The process "pretends" to continue through, but when HydraLIST opens, it's completely blank. |
|
Card 1320 View | Listing (AutoCAD Based) | Start Autolist | Hydralist Opens | None | After running an Autolist, in HydraLIST and the LINES tab you have a listing tag ID called RM |
|
Card 389 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | Upon starting the Show 3D command (S3D) the drawing immediately switches to SE isometric, reports no errors but no 3D piping is visible. Even newly drawn pipe won't elevate. Drawing successfully elevated to 3D. No errors were found |
|
Card 1091 View | Installation (Revit Based) | None | None | None | Greyed out options in the Addin Assistant and ribbons do not appear in Revit |
|
Card 660 View | HydraCALC (Standalone) | Calculate | Calculating | Process Error | Primary calc results are shown, and when selecting OK to continue back to the calc input screen, the two messages below are displayed, twice;
"The designated source node was not found in the list of pipes" OK "Calculation failed for an unknown reason" OK Process Error Hydcalc |
|
Card 1301 View | Riser Nipples (AutoCAD Based) | Edit Riser Nipples | None | Other | When selecting a vertical pipe/riser nipple hydrapipe, the PROPERTIES window shows "no selection" instead of "hydrapipe"
You may notice that you cannot use the 'change length' command (CL) or cannot rotate riser nipple (RRT)
|
|
Card 267 View | 3D Modeling (AutoCAD Based) | Switch To Edit Mode | None | None | Hydrapipe - vertical pipe issue Switching to Edit Mode leaves HydraPipes in Hydrapipe layer. Then when trying to show system model you get an AutoCAD message box "Please Switch to Edit Mode. Then try again." Switch to Edit.... |
|
Card 1293 View | HydraCAD (Revit Based) | Spacing and Layout | New Head From Selector | None | Unhandled Exception... System.ArgumentOutOfRangeException: Index was out of range |
|
Card 1205 View | HydraLIST (Revit Based) | Fab View | None | None | No error... but the view shows up in the project browser but quickly disappears after and cannot be accessed. |
|
Card 878 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Input String Was Not In A Correct Format | When defining a flexible sprinkler connection, the following error is raised ("Input string was not in a correct format"): |
|
Card 1122 View | Sprinklers (AutoCAD Based) | FSC Insert | None | None | No error reported for FSC even when maximum length is clearly exceeded
If you view the FSC properties, it's possible the HoseLength and MaxNumberOfBends values are not set. |
|
Card 986 View | HydraCALC (Standalone) | Calculate | Calculation Results | Pressure Required Is Negative | When running a calculation, the value for "pressure required" shows a negative value.
|
|
Card 1291 View | Sprinklers (AutoCAD Based) | FSC Insert | None | None | Error encountered when creating an FSC block... Can appear as either of the two shown below: |