Hydratec Inc.

Your Quick Search:

"Show Tag Locations"

Software:

Advanced Search

Total results: 102 (Closest matches are returned first)

Page:

Previous

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 946 View Listing (AutoCAD Based) Start Autolist None None

When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing.  It only shows the original tag of MAIN A 

Same can be said for line tags #LN1.1, #LN1.2, etc

Card 854 View Listing (AutoCAD Based) Start Autolist None Hydracad Error

When starting the AutoLIST process, the message box shown below pops up.  The process "pretends" to continue through, but when HydraLIST opens, it's completely blank.

Card 1320 View Listing (AutoCAD Based) Start Autolist Hydralist Opens None

After running an Autolist, in HydraLIST and the LINES tab you have a listing tag ID called RM






Card 389 View 3D Modeling (AutoCAD Based) Show System Model None None

Upon starting the Show 3D command (S3D) the drawing immediately switches to SE isometric, reports no errors but no 3D piping is visible.  Even newly drawn pipe won't elevate.

Drawing successfully elevated to 3D. No errors were found

Related HydraCARD: #853

https://hydracards.hydratecinc.com/cards/card-853

Card 1144 View Build 3D Risers (AutoCAD Based) None None None

3D Details (3D Fittings) missing, only the skipoles are showing

Card 1091 View Installation (Revit Based) None None None

Greyed out options in the Addin Assistant and ribbons do not appear in Revit

Card 660 View HydraCALC (Standalone) Calculate Calculating Process Error

Primary calc results are shown, and when selecting OK to continue back to the calc input screen, the two messages below are displayed, twice;

 

"The designated source node was not found in the list of pipes" OK

"Calculation failed for an unknown reason" OK

Process Error Hydcalc

Card 1301 View Riser Nipples (AutoCAD Based) Edit Riser Nipples None Other

When selecting a vertical pipe/riser nipple hydrapipe, the PROPERTIES window shows "no selection" instead of "hydrapipe"

 

You may notice that you cannot use the 'change length' command (CL) or cannot rotate riser nipple (RRT)

 

Card 267 View 3D Modeling (AutoCAD Based) Switch To Edit Mode None None

Hydrapipe - vertical pipe issue Switching to Edit Mode leaves HydraPipes in Hydrapipe layer. Then when trying to show system model you get an AutoCAD message box "Please Switch to Edit Mode. Then try again." Switch to Edit....

Card 1293 View HydraCAD (Revit Based) Spacing and Layout New Head From Selector None

Unhandled Exception... System.ArgumentOutOfRangeException: Index was out of range

Card 1205 View HydraLIST (Revit Based) Fab View None None

No error... but the view shows up in the project browser but quickly disappears after and cannot be accessed. 

Card 878 View Sprinklers (AutoCAD Based) FSC Setup None Input String Was Not In A Correct Format

When defining a flexible sprinkler connection, the following error is raised ("Input string was not in a correct format"):

Card 1122 View Sprinklers (AutoCAD Based) FSC Insert None None

No error reported for FSC even when maximum length is clearly exceeded

 

If you view the FSC properties, it's possible the HoseLength and MaxNumberOfBends values are not set.

Card 986 View HydraCALC (Standalone) Calculate Calculation Results Pressure Required Is Negative

When running a calculation, the value for "pressure required" shows a negative value.

 

 

Card 1291 View Sprinklers (AutoCAD Based) FSC Insert None None

Error encountered when creating an FSC block... Can appear as either of the two shown below:

Card 299 View Launching HydraCAD (AutoCAD Based) None None None

UCS is out of whack or the clockwise option is checked in units dialog Tagging

Card 979 View HydraCALC (Standalone) Calculate Calculation Results System Is -Nan(Ind) Psi

After calculating the system, the results show, "Your System Has a Deficit"

System is -nan(ind) psi over the Water Supply Curve

Card 292 View Launching HydraCAD (AutoCAD Based) Paper Space None None

In a paper space viewport, certain blocks or dimensions do not appear, even though the layer is ON and set to Plot in Current Viewport

It may appear as if the layer is not showing up, but it is really certain items in the layer

Card 386 View Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Corrupt external data 2. 3D Head Block set wrong. show fittings HydraCAD V5x

Card 21 View HydraCALC (Revit Based) Hydraulic Calculations None 200 Passes

Step 2.3 - Can also show up as This Calculation has gone 200 passes...

Page: