Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 946 View | Listing (AutoCAD Based) | Start Autolist | None | None | When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing. It only shows the original tag of MAIN A Same can be said for line tags #LN1.1, #LN1.2, etc |
|
Card 1410 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | When attempting to insert a pipe dimension you get the error "Invalid option keyword" And the command prompt says "Enter an UNDO control option" with the dialog showing your choices |
|
Card 1372 View | Opening a Drawing (AutoCAD Based) | None | None | None | When opening AutoCAD, you get an error saying "a software problem has AutoCAD to close unexpectedly" Upon reviewing the file it's crashed on, it shows HCAD_MAKEFIGHANGERLIST as the culprit |
|
Card 979 View | HydraCALC (Standalone) | Calculate | Calculation Results | System Is -Nan(Ind) Psi | After calculating the system, the results show, "Your System Has a Deficit" System is -nan(ind) psi over the Water Supply Curve |
|
Card 1407 View | Plot (AutoCAD Based) | Plot | None | None | When plotting to Bluebeam document, some HydraCAD drawing entities show up blacked out. AutoCAD view; PDF generated by Bluebeam; |
|
Card 1091 View | Installation (Revit Based) | None | None | None | Greyed out options in the Addin Assistant and ribbons do not appear in Revit |
|
Card 854 View | Listing (AutoCAD Based) | Start Autolist | None | Hydracad Error | When starting the AutoLIST process, the message box shown below pops up. The process "pretends" to continue through, but when HydraLIST opens, it's completely blank. Re-run Autolist with the drawing starting on the ground. Current run will not include any FSC information in the MISC tab in HydraList. |
|
Card 922 View | HydraCALC (Standalone) | Info Sheet | None | When viewing the final calc printout, the info sheet shows the line, text1(35) - invisible |
||
Card 573 View | HydraCALC (Standalone) | Utilities | Alter Pipe | None | Runtime 13 | Setting certain pipe diameters with specific pipe types gives an ID of 0. Eg. 1½" - SCHED 40 shows up as 0 rather than 1.61. n/a HydraCalc |
|
Card 41 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Unknown fitting in drawing, cannot continue Type SME at the command line to open 'Show Model Errors' dialog box |
|
Card 141 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Message Box | System seems to hang at this step, but eventually shows the error; Hydraulic Calculation - The system flow demand of ####.## exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO.
The calculation will not continue Calculation failed for an unknown reason May not be 1a.3 or 2.3, could be anywhere along here. |
|
Card 1346 View | Display (AutoCAD Based) | None | None | None | Line / Main tags are blocking items behind the text / tags are not transparent |
|
Card 1396 View | Listing (AutoCAD Based) | New Tag | None | Invalid Color Number | When inserting a listing tag on a pipe, you get the error, "Invalid color number" |
|
Card 1393 View | Sprinklers (AutoCAD Based) | FSC Setup | None | None | When running the "FSC Setup" to "Create FSC Definition". |
|
Card 474 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | The diameter tag HANDLE is 0000 this number is used to determin if the pipe is sloped - yielding an incorrect pipe length. Move Line / Move Main make the diameter tag HANDLE be 0000 |
|
Card 1377 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the external command... The 3D view ownerDBViewId is not locked |
|
Card 562 View | HydraCALC (AutoCAD Based) | Print Final | None | Runtime Error | Printing a calc shows this error in HydraVIEW; File not found Runtime Error 53 |
|
Card 1365 View | HydraCAD (Revit Based) | Hangers | Dialog Box | Missing Detail | When selecting Adjustable Ring Hangers for pipe sizes larger than 8" the detail does not show. |
|
Card 1358 View | 3D Modeling (AutoCAD Based) | S3D - Raise to 3D | None | None | When closing a drawing in 3D, and later re-opening and returning to 2D, some of the drawing symbols show up looking like outlines (Hangers, Sprinklers, etc) |
|
Card 1144 View | Build 3D Risers (AutoCAD Based) | None | None | None | 3D Details (3D Fittings) missing, only the skipoles are showing |