Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 849 View Launching HydraCAD (AutoCAD Based) Opening None Semantic Errors In Hd_Input.Dcl

Semantic error(s) in DCL

Card 848 View HydraCALC (Standalone) Calculation Summary Calculation Results None

Calculation runs through but flow & pressure summary are jibberish.  Such as a 'Flow required of 1.#QO gpm'

Card 847 View Launching HydraCAD (AutoCAD Based) Save None Other

Trying the SAVE or QSAVE or SAVE AS command in AutoCAD fails

"One or more objects in this drawing cannot be saved to the specified format.  The operation was not completed and no file was created."

Card 846 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # J19380

Just after starting the Autocalc Settings, the dialog box as shown below pops up and the process stops.  

Something went wrong!  Error Code J19380

Card 845 View HydraCALC Sizer (Standalone) Calculate None None

Running the 'Calculate Results' command locks up HydraCALC Sizer.

Card 844 View 3D Modeling (AutoCAD Based) System Boundary None Fatal Error

When trying to insert a System Boundary, the user gets these messages.

 

Card 843 View Head Selector (Standalone) Open None Runtime Error

 

Card 842 View Launching HydraCAD (AutoCAD Based) Display Status Line None

When user moves mouse around, Status bar moves around and displaces Paper Space tabs

Card 841 View HydraCAD Residential (AutoCAD Based) Installation Installing Many

Difficulty installing or difficulty opening HCAD-R after installing.  This is a 40 step description of the installation process which lists potential errors and how to overcome them to complete the installation and configuration.

Card 840 View Calculations (AutoCAD Based) Start Autocalcs Finish Area None

AutoCALC is creating extra node points where there shouldn't be.  In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.

 

'extra node'

'extra ref point'

'extra reference point'

'refpt'

Card 839 View HydraKEY (Security and Licensing) Add New Authorization None Failed Call To Server

A failure to call the Hydratec security server occured. 

-OR-

Hydratec Security Error

FAILED CALL TO SERVER (to Activate): Could not parse request body into json.

 

Card 838 View HydraLIST (Revit Based) Create Stocklist None Revit Could Not Complete The External Command.

Revit could not complete the external command     System.NullReferenceException

 

Card 836 View HydraCAD (Revit Based) Spacing and Layout New Head from Selector Value Cannot Be Null

Unhandled exception has occurred in a component in your application.

Card 835 View HydraLIST (Standalone) Print Labels None None

Printing labels with Bar Codes, might be no message, might be a message about missing font Free 3 of 9

Bar codes printout as letters & numbers.

Card 834 View HydraLIST (Standalone) HydraVIEW None None

No error.

Pick Setup and nothing happens.

Card 833 View HydraLIST (Standalone) Process to PDF PDF Printing Pdf Blank

PDF blank

Card 832 View Launching HydraCAD (AutoCAD Based) None None None

Unable to find Default Profile:


The profile specified as the default AutoCAD profile does not exist.  Open AutoCAD, go to Options...  <<Unnamed Profile>>...

Card 831 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Caclulating Total Lengths...

Runtime Error "13"

Type mis-match

Card 830 View HydraCALC (Standalone) HydraCALC File Save No Connectable Heads

While working on a calc file which is saved to a network location, any changes or revisions where were made, then saved, won't be there when the file is opened again.

File doesn't save

File doesn't update

 

Card 829 View HydraVIEW (Standalone) Open None Unknown Filetype

Unknown Filetype

Unknown filetype being opened - 'HLPF'

Path of the file is then shown...