Card 1094 View HydraCAD (Revit Based) Add Device None None

All the valves listed are red and can't be imported

Card 1093 View Add-Ins (Revit Based) HydraCAD Retrieve HydraCAD Revit MEP Content None

When Revit retrieves the content from ACAD it is recognizable but not really usable.  It looks all wonky / messed up.

  

Card 1092 View Add-Ins (Revit Based) HydraCAD Retrieve HydraCAD Revit MEP Content None

Retrieve HydraCAD Revit MEP Content button is missing

Card 1091 View Installation (Revit Based) None None None

Greyed out options in the Addin Assistant and ribbons do not appear in Revit

Card 1090 View Launching HydraCAD (AutoCAD Based) Opening None Unrecognized Version

When opening HydraCAD and trying to open a drawing or a template, you get the error message; 

Also happened when layers were isolated trying to burst objects

 

'unrecognized version and cannot be read'

 

Card 1089 View Collaborate (AutoCAD Based) Navisworks Toolkit None Unknown Command

When attempting to run the NWCOUT command, you get an 'unknown command' error message;

Card 1088 View Sprinklers (AutoCAD Based) Select Sprinkler None Unknown Command

When attempting to setup a sprinkler head, after clicking OK in the definition window, the command prompt looks like this and no sprinkler head is inserted;

Card 1087 View Sprinklers (AutoCAD Based) Select Sprinkler None Crash

Attempting to redefine a sprinkler head with the string 'flex' in the name/description will crash with a BAD SSGET error message if the sprinkler was not set up as an older style HydraCAD flex head

 

 

 

Card 1086 View HydraCAD (Revit Based) Hangers None None

Hangers dialog won't open:

Unhandled exception has occurred... Object reference not set to an instance of an object

Card 1085 View All (Revit Based) None None None

Hydex Security Entitlement Error

It appears that this machine is accessing a corrupt entitlement or the hasp files are out of date.

 

.

Card 1084 View All (Revit Based) Setup None None

System.Exception: Could not load reference point family symbol

Card 1083 View Collaborate (AutoCAD Based) Navisworks Toolkit None Please Click Apply And Restart Command

When attempting to create a Persistent Model, you get the error message;

Please click Apply and restart command.  Thank you.

Rinse and repeat each time

Card 1082 View Installation (Security and Licensing) None None Error Writing

While Running the HydraKey or HydraVersion Install, you recieve Error 1310.

Card 1081 View 3D Modeling (AutoCAD Based) Show System Model None Please Switch To System Model

When attempting to create a 3D model, you get the error; Please switch to System Model to Annotate Drops and Sprigs plus

System.NullReferenceException: Object reference not set to an instance of an object

at HCADexports.RevitConversion.create_hydrapipes_from_db()

at HCADexports.RevitConversion.create_hydrafittings_from_db(List'1 pipes, List'1 heads)

 

Card 1080 View HydraBID (Standalone) Create New Assembly None None

When trying to create a new assembly, this error shows...But I am already in the Assembly Sheet of the Complete Parts List

Card 1079 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

Failure at Step 5a.3b

Card 1078 View HydraCAD (Revit Based) Add Device Select None

I updated my database and I still get the old valve

Card 1077 View HydraCALC (Standalone) Print Final Results Discrepancy

Reviewing the results you notice a discrepancy between the k-factor of an equivalent k versus a sprinkler head using that equivalent k-factor

 

In the example below, EQ02 has a k-factor of 5.37.  Reference point 1 is supposed to use the k-factor of EQ02 (5.37) but in fact is using a different value (5.36).

 

Card 1076 View HydraCAD (Revit Based) Couplings Add Couplings None

No error, but when trying to use Add Couplings, Revit stops responding and the couplings are never placed.

Card 1075 View HydraLIST (Revit Based) Tag Setup Ok None

ERROR: No fittings were found on the selected pipe