Hydratec Inc.

Standalone Cards

Total: 268

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 922 View HydraCALC (Standalone) Info Sheet Print None

When viewing the final calc printout, the info sheet shows the line,

text1(35) - invisible

Card 913 View HydraCALC (Standalone) Calculate Calculating Error In Calc Engine

While trying to calculate a job, an error message pops up saying the following

"Error in Calc Engine"

Error in processing data of calculation;

-If this is a grid, uncheck 'Autopeak' and try again or,

-Confirm the node you set as the calculation source node exists in your input or,

- Check for incorrect values in your densities, areas or pressures

Card 911 View HydraCALC (Standalone) None None Hydraulic Calculation - Error

During running your calculation, and after receiving the summary regarding your safety margin, you get a similar error.

You'll then likely get these errors, up to 3 times.

 

Be aware these windows may be BEHIND the calc window, so move the calc window out of the way if it looks like it has crashed or is hung

 

Card 908 View HydraCALC (Standalone) None None Runtime Error

Trying run a calculation as stand-alone, or via AutoCAD/AutoCALC or Revit/AutoCALC, you get this error message;

Run-time error 339:  Runtime error 339  Runtime 339
Component 'MSCOMCTL.OCX' or one of its dependencies not correctly registered: a file is missing or invalid

It's likely a job without a pump works, but one with a pump crashes
 

Card 895 View HydraCALC (Standalone) Print None Runtime Error

When trying to print final, the dialog box HydraVIEW, Run-time error 9, Subscript out of range

Card 893 View HydraCALC (Standalone) Company Information Edit Company Info Missing Company Info

When trying to edit the company information by going to the menu [Utilities|Alter Company Information], you get the error saying, "Error trying to edit company information", Please get a copy of {\...\Company1.dat} onto this computer".

Card 887 View HydraCALC (Standalone) Print Final None No Connectable Heads

When attempting to print a final calc, nothing happens and HydraVIEW doesn't open.

You can test this by trying to manually open HydraVIEW.  Go to the Windows START button, scroll down to the letter H, select Hydratec v50 Software, then select HydraVIEW.  It should open to a blank job, but if nothing happens, see below for the possible solution.

You can also manually attempt to navigate to this folder, then double-click HydraVIEW.EXE;

"C:\HES\Common\Ver50\HydraVIEW.EXE"

Card 882 View HydraCALC (Standalone) Company Information None Missing Company Info

When trying to add information for a new company [Utilities|Alter Company Info], you get the error message; 

"Missing company data file" "Error trying to edit company information" "Please get a copy of Company1.dat"

Card 879 View HydraCALC (Standalone) Open None Runtime Error

When trying to open HydraCALC, the user gets a Runtime Error 5, "Invalid Procedure Call or Argument"

Card 872 View HydraCALC (Standalone) None None Runtime Error

When opening HydraCALC, user is greeted with

Run-time error 62

Input past end of file

 

Runtime 62 Runtime Error 62

Page: