Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 909 View | HydraCAD (Revit Based) | Hangers | Dialog Box | None | List of available hangers is blank or very short... Missing Basic Adjustable Ring Hanger Missing Hanger Families |
|
Card 340 View | Hangers (AutoCAD Based) | Create 3D Hangers | None | None | Create 3D Hangers command did not created 3D hangers for the #01B hanger assembly but it did for all other hanger assembly types. #01B 3D hanger information is not in the DAT file. HydraCAD v50 |
|
Card 258 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | Hanger length attribute is missing. The hanger inserts only the assembly number even if the HIDE NUMBER box is checked in the Hanger Setup. A V45 hanger block is in the drawing. It has only one attribute value & can display only the number. HydraCAD v50 |
|
Card 1033 View | Hangers (AutoCAD Based) | Auto Hang | None | Bad Argument Type: Numberp: Nil | When trying to insert a hanger, either with layout hangers, single hangers or autohang, you get this error message It may also put a single random hanger out in space then kick you out of the command |
|
Card 27 View | HydraCAD (Revit Based) | Hangers | Pick ... | None | Setup a hanger, insert a hanger, see a hanger insert, then the Run Setup dialog box comes up, pick OK and *Poof*, no hanger. |
|
Card 1068 View | HydraCAD (Revit Based) | Hangers | Dialog Box | None | Hanger Assembly dropdown list is incomplete. |
|
Card 347 View | Hangers (AutoCAD Based) | Create 3D Hangers | None | None | 3D hangers appear 'on the floor' Hangers |
|
Card 1161 View | HydraCAD (Revit Based) | Hangers | Ok | None | When trying to insert a ring hanger with trapeze pipe, the trapeze pipe won't show up on the hanger |
|
Card 440 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | Hangers are computer generated and there is no TOS deflines or the drawing was not raised first. creating |
|
Card 992 View | HydraCAD (Revit Based) | Hangers | Pick Point | None | No error message but command simply stops after one brace...
When running the hanger command for sway bracing, it will only add one brace.
|
|
Card 1072 View | HydraCAD (Revit Based) | Hangers | None | Unhandled Exception | When selecting the Hangers button, this error displays. |
|
Card 1086 View | HydraCAD (Revit Based) | Hangers | None | None | Hangers dialog won't open: Unhandled exception has occurred... Object reference not set to an instance of an object |
|
Card 150 View | Listing (AutoCAD Based) | Start Autolist | None | None | V45 converted to V50, the hangers show up in list but no cut dimensions on drawing |
|
Card 752 View | HydraLIST (Standalone) | Process | None | None | Missing Code type for hangers assmnumber not found n/a 50.20.1 |
|
Card 740 View | HydraLIST (Standalone) | Process | None | Runtime Error | Error occurs when trying to process a list created by AutoLIST. This may have happened when LIST HANGERS BY LINE NUMBER was checked in the AutoLIST Setup. Runtime Error 3022 |
|
Card 247 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | 1. HydraCAD v45 SMaRT drawing in HydraCAD v50 bad argument HydraCAD v50 |
|
Card 394 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | older or bad windows video driver file creating 52 |
|
Card 293 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | ??? Connection Failed listing tags |
|
Card 367 View | Hangers (AutoCAD Based) | Create 3D Seismic Braces | None | None | older or bad file inserting 52 |
|
Card 1074 View | HydraCAD (Revit Based) | Hangers | Ok | None | No error, but when trying to put a seismic brace on a vertical pipe, it won't place itself down. It keeps prompting to make a selection. |