Your Quick Search:
"Delete Ref Points"
Software:
Total results: 145 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
| Card 97 View | Calculations (AutoCAD Based) | Reference Points | None | None | 1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location 2. New ref points in HydraCALC are not using the values of the HYD ref points. |
|
| Card 1403 View | HydraCALC (Revit Based) | All Ref Points | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 840 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | AutoCALC is creating extra node points where there shouldn't be. In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.
'extra node' 'extra ref point' 'extra reference point' 'refpt' |
|
| Card 1402 View | HydraCAD (Revit Based) | Pretty Sprinklers | None | None | When I use Pretty Sprinklers, all the nodes that were attached to my sprinklers when using All Ref Points disappeared. |
|
| Card 1376 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | Error placing Reference Points or Demand Area annotation... The 3D view ownerDBViewId is not locked. |
|
| Card 11 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | 1a.1 | Step 1a.1 - Error box - missing Pipe Type pointing to Ref 1 & Ref 2
can also be Step 1a.4 |
|
| Card 391 View | Calculations (AutoCAD Based) | Dummy Reference Points | None | None | Dummy reference points cannot find the dummy ref point block in the drawing's block table. **Possible there's a missing registry entry** Dialog box 52.04 |
|
| Card 70 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Duplicated Hydraulic Ref Point |
Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID Duplicated hydraulic ref points
|
|
| Card 526 View | Calculations (AutoCAD Based) | Reference Points | None | None | Bad ref point block Dialog box |
|
| Card 1166 View | Launching HydraCAD (AutoCAD Based) | Opening | None | Shortcut Error | When trying to open HydraCAD after a recent install, you get this error or one similar to it; "Missing shortcut", Windows is searching for acad.exe. To locate the file yourself, click Browse.
AND Problem with Shortcut - The item 'acad.exe' that this shortcut refers to has been changed or moved, so this shortcut will no longer work properly. Nearest match based on size, date, and type: Do you want to fix this shortcut to point to this target or do you just want to delete it?
|
|
| Card 1457 View | HydraCALC (Revit Based) | All Ref Points | None | System.Nullreferenceexception: | When trying to add reference points, none are added and this error shows:
|
|
| Card 1422 View | HydraCALC (Revit Based) | All Ref Points | None | System.Nullreferenceexception: | When trying to add reference points, none are added and this error shows:
|
|
| Card 699 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Untitled.hlf is somehow protected and will not delete. Runtime Error 70, 70 |
|
| Card 702 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Some application unistalled or delete miscrosfot jet files form the computer. Most if not all of the files listed below are missing from either the windows/system32 folder or the program file/common/miscrosoft shared/dao folder DAO350.dll ExpSrv.dll MSJet35.dll MSJInt35.dll MSJtEr35.dll MSRepl35.dll MSRD2x35.dll MSVCRT40.dll VB5DB.dll VBAJet32.dll Runtime error 3633, 3633 |
|
| Card 1478 View | View (Revit Based) | Floor Plan | None | None |
Pipe fittings in certain views were grayed out and could not be selected, making it impossible to edit or work with them. |
|
| Card 1469 View | Piping (AutoCAD Based) | Define Pipe Elevations | None | Unhandled Exception | Error occurs when using some commands. Autodesk has just released AutoCAD 2026.1.2 - and it breaks HydraCAD. It includes a major programming change by Autodesk that will require a lot of work and a large update by us. That update is being worked on right now, along with a version of HydraCAD for AutoCAD 2027. Both are now affected by essentially the same programming change. BinaryFormatter serialization and deserialization are disabled within this application. See https://aka.ms/binaryformatter for more information. Other commands with this error; Sprinkler Layout dialog (SL command) |
|
| Card 389 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | Upon starting the Show 3D command (S3D) the drawing immediately switches to SE isometric, reports no errors but no 3D piping is visible. Even newly drawn pipe won't elevate.
Drawing successfully elevated to 3D. No errors were found |
|
| Card 13 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None |
Step 1a.1 - Error Box - User ID Duplicated Transfer to HydraCalc - Step I1a.10 System is now 'Attaching Node 2 Elevations error occurs, please report both the step number and the step description to support! Error Display Error Type User ID Duplicated Step Ref 1 Ref 2 Ref 3 I Ref 4 1a.1 |
|
| Card 1468 View | Calculations (AutoCAD Based) | Reference Points | None | None | When viewing a plot, hydraulic reference points in the HYD2 layer have thick text. Editing lineweights for the layer does not make a difference.
|
|
| Card 1021 View | HydraCALC (Standalone) | Open | Double-Click | None | Double-clicking your HydraCALC icon makes nothing happen. You do not see HydraCALC open onscreen nor on your taskbar. HydraCALC does not open other than in the task manager. If you open your task manager and see the app "Hyd_prog.exe" open but not on your taskbar, then the application is stuck in purgatory.
Another possibility may be that it's on the taskbar but not on your screen. That means it's open but offscreen. See this HydraCARD to fix that issue; HydraCARD 565 only AFTER you've checked on the solution below.
|
|
Page: