Your Quick Search:
"Connect Pipes"
Software:
Total results: 89 (Closest matches are returned first)
Page:
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
| Card 1330 View | HydraCAD (Revit Based) | Configure Head | Connect Head | None | No error, but when trying to connect a sprinkler to a pipe, connect head does not let you select a sprinkler |
|
| Card 465 View | Piping (AutoCAD Based) | Stacked Riser Nipples | None | None | stacked rn connects to first pipe and misses second pipe leaving a pipe going up to nowhere. this is caused by a floor boundary with a negative elevation adn computer generated VP |
|
| Card 1302 View | Sprinklers (AutoCAD Based) | FSC Insert | None | None | When connecting a hard pipe armover to a flexible sprinkler connection (FSC), the flex hose doesn't continue straight, instead it immediately turns 90° before curving back and down to the sprinkler head.
Even with setting the connection to OVER-DOWN
|
|
| Card 31 View | HydraCAD (Revit Based) | Spacing and Layout | Pick ... | None | When using connect heads to pipes AND the family Fire Protection Lines Threaded AND connecting three (3) or more sprinklers, one (1) pipe segment disappears during the command. |
|
| Card 591 View | HydraCALC (AutoCAD Based) | Calculate | Input | None | There is a 3 pipe connection at node point but all 3 change marks are the same. Use Velocity Pressure Input error |
|
| Card 885 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Runtime Error 6 when Attaching Fittings Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2. Trying to run a auto calc from a drawing. How do I find the referenced pipes? |
|
| Card 449 View | Calculations (AutoCAD Based) | Add Calculation Fittings | None | None | Error occurs when "Add Calculation Fittings" is used when running AutoCALC the first time after a new install. A registry entry for one of the Pipe Schedule properties is not set in the registry. (The Pipe Schedule is connected to fittings definitions.) error 75 |
|
| Card 51 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Water supply test point not connected to a pipe. Reinsert water supply\test point |
|
| Card 1145 View | HydraCALC (Standalone) | Utilities | Alter Pipe | Saving Data | Runtime 76 | When editing and saving data for pipes, fittings, or flexible connections, you get a Run-time error 76, Path not found error
|
|
| Card 1116 View | HydraCAD (Revit Based) | Spacing and Layout | None | None | After using the Spacing and Layout tool, the pipes and sprinklers are modeled but are not connected properly to each other.
|
|
| Card 1371 View | HydraCAD (Revit Based) | Connect Pipes | Raise Pipe | Command Failure For External Command | Revit could not complete the external command... Curve length is too small for Revit's tolerance
|
|
| Card 545 View | Piping (AutoCAD Based) | Auto Line | None | No Connectable Heads | No connectable heads found within distance specified for the line illustrated, or heads were already connected ...
No connectable heads message comes up, even when there are obviously heads that can be connected. Can also be error stating Please re-select line away from other lines |
|
| Card 1268 View | HydraCAD (Revit Based) | Configure Head | Connect Head | None | No Error given but Pipes look like theyy are missing after program completion.
|
|
| Card 255 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | Unhandled Exception | Bad prettypipes.dat file Bug with the new Flexible Hose Connections. Drawing with FHCs will get this error, drawings without will not get the error Unhandled Except. Dialog Box v50 |
|
| Card 659 View | HydraCALC (AutoCAD Based) | None | None | None | no error or error 13 ediiting aquivalent lengths or all the pipe disappears or file will not open after it was open intially or error or lockup during the process or error or lockup during error check Flexible Connection Flex flexhead |
|
| Card 1216 View | 3D Modeling (AutoCAD Based) | Persistent Model | None | None | When viewing your Persistent Model drawing, you see the clamshells/Pacman/bracket for the riser nipples/vertial pipes
|
|
| Card 1441 View | Installation (Revit Based) | None | None | None | Using HydraCAD buttons cause errors like Loading Shared Parameters for Pipes Failed.... |
|
| Card 267 View | 3D Modeling (AutoCAD Based) | Switch To Edit Mode | None | None | Vertical pipe issue. Switching back to Edit Mode (S2D) leaves HydraPipes in Hydrapipe layer. Then when trying to show system model again (S3D) you get an AutoCAD message box "Please Switch to Edit Mode" |
|
| Card 1436 View | Pretty Pipes (AutoCAD Based) | None | None | None | After setting specific linetypes for your piping, pretty pipes doesn't match the linetype of your pipe.
The pipe noted should show a HIDDEN pretty pipe, similar to the one below it
|
|
| Card 1423 View | HydraCALC (Standalone) | Print Final | None | When printing a final calculation, the font doesn't show fraction symbols for ¼ (quarter), ½ (half), or ¾ (three-quarters) They're replaced with ?.840, ?1.050, and ?1.660
These should look like this;
Of note, if using HydraCAD for AutoCAD, you get similar results on riser nipples/vertical pipes
|
||
Page: