Ribbon/Toolbar (software) Button Function Error Type Message
Ribbon/Toolbar (software) Button Function Error Type Message
Card 1330 View HydraCAD (Revit Based) Configure Head Connect Head None

No error, but when trying to connect a sprinkler to a pipe, connect head does not let you select a sprinkler

Card 465 View Piping (AutoCAD Based) Stacked Riser Nipples None None

stacked rn connects to first pipe and misses second pipe leaving a pipe going up to nowhere. this is caused by a floor boundary with a negative elevation adn computer generated VP

Card 1302 View Sprinklers (AutoCAD Based) FSC Insert None None

When connecting a hard pipe armover to a flexible sprinkler connection (FSC), the flex hose doesn't continue straight, instead it immediately turns 90° before curving back and down to the sprinkler head.

 

Even with setting the connection to OVER-DOWN

 

 

Card 31 View HydraCAD (Revit Based) Spacing and Layout Pick ... None

When using connect heads to pipes AND the family Fire Protection Lines Threaded AND connecting three (3) or more sprinklers, one (1) pipe segment disappears during the command.

Card 591 View HydraCALC (AutoCAD Based) Calculate Input None

There is a 3 pipe connection at node point but all 3 change marks are the same. Use Velocity Pressure Input error

Card 885 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Runtime Error 6 when Attaching Fittings

Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2.

Trying to run a auto calc from a drawing.  How do I find the referenced pipes?

Card 449 View Calculations (AutoCAD Based) Add Calculation Fittings None None

Error occurs when "Add Calculation Fittings" is used when running AutoCALC the first time after a new install. A registry entry for one of the Pipe Schedule properties is not set in the registry. (The Pipe Schedule is connected to fittings definitions.) error 75

Card 51 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Water supply test point not connected to a pipe. Reinsert water supply\test point

Card 1145 View HydraCALC (Standalone) Utilities | Alter Pipe Saving Data Runtime 76

When editing and saving data for pipes, fittings, or flexible connections, you get a Run-time error 76, Path not found error

Card 1116 View HydraCAD (Revit Based) Spacing and Layout None None

After using the Spacing and Layout tool, the pipes and sprinklers are modeled but are not connected properly to each other. 

Card 545 View Piping (AutoCAD Based) Auto Line None No Connectable Heads

No connectable heads found within distance specified for the line

illustrated, or heads were already connected ...




No connectable heads message comes up, even when there are obviously heads that can be connected. Can also be error stating Please re-select line away from other lines



Card 1371 View HydraCAD (Revit Based) Connect Pipes Raise Pipe Command Failure For External Command

Revit could not complete the external command... Curve length is too small for Revit's tolerance


Card 1268 View HydraCAD (Revit Based) Configure Head Connect Head None

No Error given but Pipes look like theyy are missing after program completion.

Card 255 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Bad prettypipes.dat file

Bug with the new Flexible Hose Connections. Drawing with FHCs will get this error, drawings without will not get the error Unhandled Except. Dialog Box v50

Card 659 View HydraCALC (AutoCAD Based) None None None

no error or error 13 ediiting aquivalent lengths or all the pipe disappears or file will not open after it was open intially or error or lockup during the process or error or lockup during error check Flexible Connection Flex flexhead

Card 660 View HydraCALC (Standalone) Calculate Calculating Process Error

Primary calc results are shown, and when selecting OK to continue back to the calc input screen, the two messages below are displayed, twice;

 

"The designated source node was not found in the list of pipes" OK

"Calculation failed for an unknown reason" OK

Process Error Hydcalc

Card 1453 View Launching HydraCAD (AutoCAD Based) None None Unhandled Exception

When opening Hydracad you get the following error:

Unhandled exception has occurred in a component in your

application. If you click Continue, the application will ignore this error

and attempt to continue.

 

Retrieving the COM class factory for component with CLSID

{44D62FAE-67A7-4131-BF38-489CDFE44738} failed due to the

following error: 80070005 Access is denied. (Exception from

HRESULT: 0x80070005 (E_ACCESSDENIED)).

Card 1452 View Launching HydraCAD (AutoCAD Based) None None Unhandled Exception

When opening Hydracad you get the following error:



Unhandled exception has occurred in a component in your

application. If you click Continue, the application will ignore

this error and attempt to continue.

Retrieving the COM class factory for component with

CLSID {44D62FAE-67A7-4131-BF38-489CDFE44738}

failed due to the following error: 80070424 The specified

service does not exist as an installed service. (Exception

from HRESULT: 0x80070424).

Card 1451 View 3D Modeling (AutoCAD Based) Show System Model None Unhandled Exception

Raising to 3D and you get this error;

Inline image

Exception Occured at AddURLToHyperlinks :: HydraHeads

System.Runtime.InteropServices.COMException (0x80040154): Retrieving the

COM class factory for component with CLSID

{44D62FAE-67A7-4131-BF38-489CDFE44738} failed due to the following error:

80040154 Class not registered (Exception from HRESULT: 0x80040154

(REGDB_E_CLASSNOTREG)).

Card 1407 View Plot (AutoCAD Based) Plot None None

When plotting to Bluebeam document, some HydraCAD drawing entities show up blacked out.

AutoCAD view;