Hydratec Inc.

Standalone (Hydracalc)

Total: 89

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 887 View HydraCALC (Standalone) Print Final None No Connectable Heads

When attempting to print a final calc, nothing happens and HydraVIEW doesn't open.

You can test this by trying to manually open HydraVIEW.  Go to the Windows START button, scroll down to the letter H, select Hydratec v50 Software, then select HydraVIEW.  It should open to a blank job, but if nothing happens, see below for the possible solution.

You can also manually attempt to navigate to this folder, then double-click HydraVIEW.EXE;

"C:\HES\Common\Ver50\HydraVIEW.EXE"

Card 882 View HydraCALC (Standalone) Company Information None Missing Company Info

When trying to add information for a new company [Utilities|Alter Company Info], you get the error message; 

"Missing company data file" "Error trying to edit company information" "Please get a copy of Company1.dat"

Card 879 View HydraCALC (Standalone) Open None Runtime Error

When trying to open HydraCALC, the user gets a Runtime Error 5, "Invalid Procedure Call or Argument"

Card 872 View HydraCALC (Standalone) None None Runtime Error

When opening HydraCALC, user is greeted with

Run-time error 62

Input past end of file

 

Runtime 62 Runtime Error 62

Card 869 View HydraCALC (Standalone) Open None Runtime Error

When opening HydraCALC, a runtime-error 380 pops up.

Invalid property value

Card 868 View HydraCALC (Standalone) Open None Corrupt .Wxf

When opening a specific cac file you get this error

Other calc files open fine

Card 861 View HydraCALC (Standalone) Open None Loadregvalue For Strinstalldrive

When opening HydraCALC or trying to run a calculation, the dialog boxes below appear. 

"Loading from Master Data Location" 

"LoadRegValue for StrInstallDrive MasterLoad Form|Activaate = C:"

After clicking OK or pressing ENTER, HydraCALC will open or finish up the calculation

 

 

 

Card 856 View HydraCALC Sizer (Standalone) Open None Runtime Error

When trying to open HydraCALC Sizer, a 'run-time error 76', Path not found error pops up and the program doesn't open.

Card 855 View HydraCALC (Standalone) Info Sheet None Runtime Error

When attempting to view the Info Sheet, the following error message pops up

Card 850 View HydraCALC (Standalone) None None None

A grid system was processed from HydraCAD to HydraCALC but the calc file did not have L (left) and R (right) markers for autopeaking.

 

 

 

Page: