Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 502 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Bad HCAD_ENV.INI asks for scale factor command prompt n/a |
|
Card 314 View | Piping (AutoCAD Based) | Move Line | None | None | Rounding issue |
|
Card 238 View | Piping (AutoCAD Based) | Riser Nipple Setup | None | None | 1. Install may not have configured properly. 2. Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any |
|
Card 375 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Unknown 2013 V52 |
|
Card 455 View | Piping (AutoCAD Based) | Edit Riser Nipples | None | None | Using AutoCAD's ROTATE command will not rotate a VP HydraCAD v52+ |
|
Card 246 View | Piping (AutoCAD Based) | Insert One RN | None | Runtime Error | 1. Trying to insert an RN on a drawing that has not been converted to v50 2. An incorrectly edited VP from v45 has bad text Runtime error 9 |
|
Card 424 View | Piping (AutoCAD Based) | Riser Nipple Setup | Dialog Box | None | Avast Virus Checker believes the file has a virus n/a Dialog Box Acad 2015 |
|
Card 244 View | Piping (AutoCAD Based) | Edit Riser Nipples | None | None | Insert RN , it asks for Higher\lower pipe then dissapears. Probalble bad configuration dissapear |
|
Card 336 View | Piping (AutoCAD Based) | Insert One RN | None | None | Riser Nipple cut dimension changed to the wrong value after going into the 3D System Model. The Riser Nipple show the wrong takeout value for the sp TakeOut & ep TakeOut properties. This was caused by the SHOW FITTINGS command. HydraCAD v5x.any |
|
Card 426 View | Piping (AutoCAD Based) | Edit Riser Nipples | None | None | unknown blank properies pallete |