Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 549 View 3D Modeling (AutoCAD Based) Show System Model None None

Drawing zooms out to expected isometric view as if 3D System Model has been completed. No 3D Pipe can be found. Unknown cause No 3D Pipe Seen All

Card 270 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Video Driver out of Date -or- 2. AutoCAD MEP has a .dbx file interfering with our drawing HydraCAD

Card 272 View 3D Modeling (AutoCAD Based) Show System Model None None

The CURRENT LAYER in the drawing is LOCKED. Show System Model process stops on Step 13 of 28 while adding RN Fittings to the drawing. Picking the 2D Switch to Edit Mode button removes the Hydrapipes and the riser nipples. Show System Model HydraCAD V51

Card 519 View 3D Modeling (AutoCAD Based) Switch To Edit Mode None None

AutoCAD Support file search path is pointing to extra, incorrect paths. Usually caused by migrating settings during install rather than running a clean install. n/a HydraCAD v53 - Acad 2016

Card 398 View 3D Modeling (AutoCAD Based) Switch To Edit Mode None None

1. Important layers locked or frozen. 2. User had OPHEAD block in ACC1 layer Internal error

Card 373 View 3D Modeling (AutoCAD Based) Show System Model None None

issue with drawing dictionary making model

Card 423 View 3D Modeling (AutoCAD Based) Show System Model None None

May have to do with sprinkler heads not defined in the drawing Exception Occured Dialog box HydraCAD

Card 537 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Important layers such as SPRKDAT1 through SPRKDAT4 are lower case instead of upper case. 3d modeling

Card 361 View 3D Modeling (AutoCAD Based) Show System Model None None

so far this has only been a problem with AutoCad Mechanical - bad support path entries Acad Mechanical

Card 483 View 3D Modeling (AutoCAD Based) Show System Model None None

The rotation of the sprinkler head symbol in the DETAILS layer is the cause of the problem. After using SFS - The sprinkler connector for the side outlet flex is rotated to the same angle as the sprinkler head symbol in the DETAILS layer. show flexible sprinkler