| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 125 View | Calculations (AutoCAD Based) | Tyco FDT | None | Runtime 53 | After entering coversheet data for the Tyco Fluid Delivery Calc, an error message of; Miscfunc Run-time error '53' File not found *.tych |
|
| Card 141 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Message Box |
System seems to hang at this step, but eventually shows the error; Hydraulic Calculation - The system flow demand of ####.## exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO.
The calculation will not continue Calculation failed for an unknown reason May not be 1a.3 or 2.3, could be anywhere along here. |
|
| Card 121 View | Calculations (AutoCAD Based) | Start Autocalcs | None | 0 | When starting the AutoCALC process, you get this error;
Could not find fitting match for Pump Only/Test Point Please check!! You also see an Accessing Database window with a partial green progress bar. No Operating Heads of Flows Found!! Please check...
|
|
| Card 112 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None |
No Operating Heads or Flows found!! Please check... |
|
| Card 47 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | This job has gone 200 or more passes without balancing. |
|
| Card 55 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Unhandled Exception | Unhandled exception: Input string not in correct format |
|
| Card 647 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Runtime Error 7 Out of memory run-time error 7 run time error 7 Runtime Error 7 Miscfunc |
|
| Card 491 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | No error but the AutoCALC process takes a very long time and is slow. No error, just hangs while using 100% RAM. Usually around step 2.3
|
|
| Card 395 View | Calculations (AutoCAD Based) | Add Calculation Fittings | None | None | Error 52 trying to insert fittings for calculations. Error 71 disk not ready error trying to use the sizing button. error 52 or 71 |
|
| Card 130 View | Calculations (AutoCAD Based) | Reference Points | None | None | No error, but inserting a HYD hydraulic reference point will use the coordinates as the node ID. If you check the properties of the block, the VALUE & LOCATION values are swapped. |
|