Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 438 View Cleanup (AutoCAD Based) Cloud None None

The cloud command does not finish correctly, when user right-clicks to close it. Cloud Command

Card 386 View Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Corrupt external data 2. 3D Head Block set wrong. show fittings HydraCAD V5x

Card 508 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

User drew own entities in FLEXPIPE Layer. That layer is only to be used by HydraCAD Unhandled Except. V50

Card 255 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Bad prettypipes.dat file

Bug with the new Flexible Hose Connections. Drawing with FHCs will get this error, drawings without will not get the error Unhandled Except. Dialog Box v50

Card 253 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Missing or frozen layer Unhandled Except. v50

Card 499 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Pretty Pipes requires line type TRACKS. This line type is missing from the drawing. Unhandled Except. v50

Card 527 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Unhandled Exception has occurred in a component in your application

Index was out of range. Must be non-negative and less than the size of the collection.

Card 472 View Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Bad PRETTYPIPES.DAT file

2. corrupt xrefs

3. Irregular linetypes in the drawing.

4. Bad Hcad_Toolbox.dll file eBadLinetypName V53.04

Card 1399 View Calculations (AutoCAD Based) Start Autocalcs None Runtime 6

When starting AutoCALC the v50 Fuel Gauge stops at step 1a.4 plus you get a Run-time error 6; Overflow 

Working on pipe from Node ### to Node ### with a fitting of ? and a diameter of / pipe type of 0.5 / SCHED-40 where the pipe id = ### 

Card 1391 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

When performing AutoCalc, the following error is displayed.

Unhandled Exception... startIndex cannot be larger than the length of string.
(Parameter 'startIndex').


Page: