AutoCAD Based (Calculations)
Total: 122
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 137 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | Unhandled Exception When clicking the 'Finish Area #' button at the completion of the AutoCALC process, a diablob box pops up; "Object reference not set to an Instance of an object" Just in time JIT Just-in-time System.NullReferenceException: CalcingNameSpace.AutoCalcForm.redButton |
|
Card 136 View | Calculations (AutoCAD Based) | Calc Check Ups | None | None | Running AutoCALC checkups on a drawing causes AutoCAD to crash out AutoCAD Application has stopped working A problem caused the program to stop working correctly. Windows will close the program and notify you if a solution is available. |
|
Card 135 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | During the AutoCALC process, it gets hung up at step 5a.3b. Re-Ordering Pipe Paths - Phase 2
|
|
Card 134 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | After 'finishing area' then exiting out of the Calc Setup screen, no HYD2 (white) reference points are inserted on the drawing Missing Reference Points No Reference Points |
|
Card 133 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | The specified remote node does not have a k-factor. Please fix your input. On Pass 1 Calculation Failed for an unknown reason. |
|
Card 132 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Transfer to HydraCALC Step 1a.2 Loading Fitting Exchange Data Run-time 9 Runtime 9 Run-time Error 9 Runtime Error 9 |
|
Card 131 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Runtime Error | After clicking the 'Calc Area 1' button, the Runtime Error 5 immediately pops up. Run-time Error 5, Invalid Procedure Call or Argument |
|
Card 130 View | Calculations (AutoCAD Based) | Reference Points | None | None | No error, but inserting a HYD hydraulic reference point will use the coordinates as the node ID. If you check the properties of the block, the VALUE & LOCATION values are swapped. |
|
Card 129 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Calc moves very slowly or hangs and machine memory goes to 100% (all other programs seemto work fine except calcs) lag slow hang |
|
Card 128 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | When trying to start the Autocalc process, the user gets a Runtime Error 7, Out of memory |