AutoCAD Based Calculations (Ribbon/Toolbar/Location)

Button: Start Autocalcs Function: Finish Area

Description:

After 'finishing area' then exiting out of the Calc Setup screen, no HYD2 (white) reference points are inserted on the drawing Missing Reference Points No Reference Points

Solutions:

Cause:

User didn't have scale factor in drawing

Solution:

Check USERR2 to see if something other than 0 is set. If the value is 0, user didn't set a scale factor in their drawing. They should re-insert the working drawing into a new drawing which was started with a template.