| Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
| Card 1285 View | Plot (AutoCAD Based) | Plot | None | Missing Pipe | When using 'Publish selected layouts' or doing a batch plot in AutoCAD 2024, the riser nipple/vertial pipe does not display correctly. It'll either be missing outright or a proxy bounding box will be in its place. If you plot a single sheet, it works fine.
AutoCAD 2024 batch plot
AutoCAD 2024 single plot
|
|
| Card 1303 View | HydraVIEW (Standalone) | Process Stock List | None | Runtime Error | When double-clicking an .HVUF file, you get a Run-time error 321 Invalid file format
|
|
| Card 878 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Input String Was Not In A Correct Format | When defining a flexible sprinkler connection, the following error is raised ("Input string was not in a correct format"):
|
|
| Card 1122 View | Sprinklers (AutoCAD Based) | FSC Insert | None | None | No error reported for FSC even when maximum length is clearly exceeded
If you view the FSC properties, it's possible the HoseLength and MaxNumberOfBends values are not set.
|
|
| Card 807 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Unhandled Exception | When trying to open the dialogue box to define a Flexible Sprinkler connection, the following message box error appears.
Could not find file; FSC-INSERTDEFLINE.txt |
|
| Card 637 View | HydraCALC (Standalone) | Print Final | None | Runtime Error | Final Printout Runtime 481 Invalid File Runtime 481 |
|
| Card 1297 View | HydraLIST (Standalone) | HydraLIST Wizard | None | None | When accessing a HydraLIST wizard, this error appears:
|
|
| Card 1273 View | Launching HydraCAD (AutoCAD Based) | Opening | None | None | When opening HydraCAD, you get this error message or something similar;
AutoCAD Warning The following shortcuts in the search were invalid and ignored:
After clicking OK, HydraCAD will open up, albeit very slowly, and almost every step will take an significant amount of time, for example 45 seconds to start a new drawing or to size a pipe
|
|
| Card 1028 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | None | 0 | When trying to insert a sprinkler head, this window pops up;
Pick head insertion point. Pick any point besides endpoint to break into pipe. Can't find file in search path *Invalid* |
|
| Card 832 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Unable to find Default Profile:
|
|