Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
AutoCAD Based Calculations (Ribbon/Toolbar/Location)
Description:
Runtime Error 7 Out of memory run-time error 7 run time error 7 Runtime Error 7 Miscfunc
Program was working fine, but all of a sudden, any calculation WITH A PUMP will generate this error. Cause: Possibly due to Windows Updates and or a combination of Office 365 + Windows 7 (and now Win 10 as well)
The only solution so far has been to re-install HydraCALC only then run the update, (not necessary for HydraCAD re-install.)
1. Close HydraCALC and rename the folder C:\HES\HydraCALC to C:\HES\HydraCALC_OLD. This forces the install to create a new file and folder structure rather than relying on older files and not overwriting them.
2. Downloaded the HydraCALC INSTALL from our website; Shared Folders\Customer Fulfillment\HydraCALC\Installs\ HydraCALC V50.## Install.ZIP
3. Download the HydraCALC UPDATE from the website; Shared Folders\Customer Fulfillment\HydraCALC\Updates\ HydraCALC V50.## Rev#.EXE
4. Extract the contents of the .ZIP file to a new folder.
5. Go to the newly created folder then run SETUP.EXE and follow through the prompts.
6. Fully shut down then turn on the computer (NOT A RESTART)
7. Turn on the computer then run the UPDATE file
8. Open HydraCALC
Our first test is to open this test job; "C:\HES\HydraCALC\Ver50\Data\Jobs\Example Jobs\Hydratec Example Pump.wxf" and try it. [GAB 02/26/19]