Ribbon/Toolbar (software) Button Function Error Type Description
Ribbon/Toolbar (software) Button Function Error Type Description
Card 453 View 3D Modeling (AutoCAD Based) Show System Model None None

Possible bad System Boundary.

Card 474 View Couplings (AutoCAD Based) Insert Couplings None None

The diameter tag HANDLE is 0000 this number is used to determin if the pipe is sloped - yielding an incorrect pipe length. Move Line / Move Main make the diameter tag HANDLE be 0000

Card 246 View Piping (AutoCAD Based) Insert One RN None Runtime Error

1. Trying to insert an RN on a drawing that has not been converted to v50 2. An incorrectly edited VP from v45 has bad text Runtime error 9

Card 352 View Calculations (AutoCAD Based) Figure Head Area Dialog Box None

APQ block is not in the block table FATAL ERROR Dialog Box HydraCAD v52

Card 308 View Sprinklers (AutoCAD Based) Insert Sprinkler Head Block Definition None

Text is the wrong size due to DIMTXT setting. Possibly caused by changing annotative scales. V50/V51

Card 424 View Piping (AutoCAD Based) Riser Nipple Setup Dialog Box None

Avast Virus Checker believes the file has a virus n/a Dialog Box Acad 2015

Card 409 View Collaborate (AutoCAD Based) Revit Toolkit Create Revit Link To Drawing None

1. Loading Revit content into a non-MEP template (ie Construction or Architectural template) Revit

Card 495 View Collaborate (AutoCAD Based) Revit Toolkit Create Revit Link To Drawing None

1. Our Addin file is looking in the wrong location for our Revit tools Revit

Card 467 View Persistent Model (AutoCAD Based) Export None None

The lines or mains do not get the pretty pipes applied. The layer is all lower case. Lines or Mains missing

Card 163 View Listing (AutoCAD Based) Listing Check Ups None None

During checkups, the process abruptly ends and reports "Exception occurred" on the command prompt Command prompt