Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 762 View | HydraLIST (Standalone) | Print Data Reports | Text | No Connectable Heads | Print setup options have been changed in either the Sheet Selection, General Setup or Prinout Order. |
|
Card 575 View | HydraCALC (AutoCAD Based) | Info Sheet | None | Runtime Error | Runtime error 75: Path/file access error Runtime error 75 |
|
Card 587 View | HydraCALC (AutoCAD Based) | Test Point | None | Runtime Error | Invalid Property Value Runtime 380 |
|
Card 784 View | HydraLIST (Standalone) | Print Data Reports | None | None | The checkbox for 'Print Kits Only' is turned on n/a n/a n/a |
|
Card 646 View | HydraCALC (AutoCAD Based) | K / Flow | Right Click | No Connectable Heads | When you right-click the K/Flow column, saved equivalent K-factors are not visible in the list of values even if they're present in the 'Equivalent K Piping' tab. n/a HYD 50.3.50 |
|
Card 124 View | (AutoCAD Based) | None | None | Runtime Error | Runtime Error 53, File Not Found HydexVB.DLL Transfer to HydraCALC |
|
Card 598 View | (AutoCAD Based) | None | None | Runtime Error | Runtime Error 5 Invalid Procedure Call or Argument |
|
Card 38 View | HydraCAD (Revit Based) | Spacing and Layout | Opening | Autodesk.Revit.Exceptions.Invalidobjectexception | Using the Sprinkler Spacing and Layout tool: Revit encountered a Autodesk.Revit.Exceptions.InvalidObjectException: The referenced object is not valid, possibly because it has been deleted from the database, or it's creation was undone. |
|
Card 37 View | HydraCAD (Revit Based) | Spacing and Layout | Pick ... | Command Failure For External Command | Revit could not complete the external command Object Reference not Valid |
|
Card 36 View | HydraLIST (Revit Based) | Create Stocklist | Return To Revit | None | Line/Main annotations do not populate with Line/Main numbers after running the calculation. |
|
Card 35 View | HydraCALC (Revit Based) | Define Supply | Pick | None | Too many Water Supplies! error message when using the Define Water Supply function |
|
Card 15 View | HydraCAD (Revit Based) | None | None | None | Error Message - The duct/pipe has been modified to be in the opposite direction causing the connections to be invalid. The referenced object is not valid, possibly because it has been deleted from the database, or its creation was undone. |
|
Card 34 View | HydraCALC (Revit Based) | Hydraulic Calculations | Return To Revit | Command Failure For External Command | Error placing Reference Points or Demand Area annotation.: System NullReferenceException: Object reference not set to an instance of an object. nodes reference finish |
|
Card 33 View | View (Revit Based) | 3D View | Default 3D View | None | When making a 3D view, nothing shows up. |
|
Card 32 View | HydraCAD (Revit Based) | None | None | None | There are no ribbons visible after installing the software. The HydraCAD ribbon is missing. |
|
Card 31 View | HydraCAD (Revit Based) | Spacing and Layout | Pick ... | None | When using connect heads to pipes AND the family Fire Protection Lines Threaded AND connecting three (3) or more sprinklers, one (1) pipe segment disappears during the command. |
|
Card 30 View | HydraCALC (Revit Based) | None | None | Unhandled Exception | Unhandled Exception... Details... System.NullReferenceException: Object reference not set to an instance of an object. at HCAD_HUI.frmPipeTypeSchedule.cmdContinue_Click |
|
Card 29 View | HydraCAD (Revit Based) | Spacing and Layout | Pick ... | None | Inserting sprinklers using the spacing an layout tool Import Errors message box - message Autodesk.Revit.InvalidOperationsException: failed to insert transition |
|
Card 28 View | HydraCAD (Revit Based) | Insert Pump | OK | Command Failure For External Command | Revit could not complete the external command.... Details: Name must be unique... At HCAD_Revit_Tools.CAD3.Insert_Pump.Go |
|
Card 27 View | HydraCAD (Revit Based) | Hangers | Pick ... | None | Setup a hanger, insert a hanger, see a hanger insert, then the Run Setup dialog box comes up, pick OK and *Poof*, no hanger. |