AutoCAD Based HydraCALC (Ribbon/Toolbar/Location)

Button: System Piping Function: Input Error Type: Runtime Error

Description:

When right clicking in the fitting column, user gets Runtime Error 5: Invalid procedure Call or Argument Runtime error 5 MiscFunc

Solutions:

Cause:

1. one or more short names for defined fittings have more characters than are allowed for short names.

Solution:

1. Go to Utilities pulldown menu, Alter Pipe/Fittings and shorten the short names to be less than 6 characters (v50.3.44 or earlier) or less than 7 characters (v50.3.45 or later)