| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 460 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | Unknown n/a Pipe diameters 53+ |
|
| Card 182 View | Listing (AutoCAD Based) | Start Autolist | None | None | Run-time error 70 Permission denied Runtime Error 70 |
|
| Card 293 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | ??? Connection Failed listing tags |
|
| Card 367 View | Hangers (AutoCAD Based) | Create 3D Seismic Braces | None | None | older or bad file inserting 52 |
|
| Card 168 View | Listing (AutoCAD Based) | Start Autolist | None | None | HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method |
|
| Card 499 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | Unhandled Exception | Pretty Pipes requires line type TRACKS. This line type is missing from the drawing. Unhandled Except. v50 |
|
| Card 334 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via Parts Tree | None | None | 1) Inserting 3d fittings is very slow & you must hit enter several times to get through the command. Must pick Enter or OK for each fitting. 2) Could also be related to an AutoCAD drawing variable setting. |
|
| Card 599 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Screen shows calcing Pump, then getting error 53. Pump calc not calcing Run time 53 |
|
| Card 527 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | Unhandled Exception | Unhandled Exception has occurred in a component in your application |
|
| Card 412 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | AutoCAD entities too far out in space for revit to handle |
|
| Card 239 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | None | None | Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any |
|
| Card 472 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | None | 1. Bad PRETTYPIPES.DAT file 2. corrupt xrefs 3. Irregular linetypes in the drawing. 4. Bad Hcad_Toolbox.dll file eBadLinetypName V53.04 |
|
| Card 480 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via Parts Tree | None | Unhandled Exception | 3dends folder or files missing unhandled exception |
|
| Card 249 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Interestingly PDMODE is set to 1. This means that there is no node point at the insertion of these sizes, so the sizes are not found. |
|
| Card 307 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | All pipe is in the branch line (SPRKDATB) layer solid pipes 3d modeling |
|
| Card 306 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Setting incorrect |
|
| Card 370 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | 1. dry pendent sprinkler is defined in the drawing and cannot be generated as Revit content Retrieve content Revit revit Link 4-2 |
|
| Card 411 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | Unknown, but likely that creation of Revit content will still be accomplished. |
|
| Card 186 View | Listing (AutoCAD Based) | Start Autolist | None | Unhandled Exception | AutoCAD Error Aborting FATAL ERROR: Unhandled Access Violation Reading 0x00e0 Exception at [hex code here] Acad 2019 hex code; 2D92713Eh Fatal Error
Hex code a51b726eh |
|
| Card 100 View | Calculations (AutoCAD Based) | Start Autocalcs | Sizing | Runtime Error | Runtime error 71 Runtime error 52 |
|
Page: