Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 527 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Unhandled Exception has occurred in a component in your application

Index was out of range. Must be non-negative and less than the size of the collection.

Card 412 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None None

AutoCAD entities too far out in space for revit to handle

Card 239 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any

Card 472 View Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Bad PRETTYPIPES.DAT file

2. corrupt xrefs

3. Irregular linetypes in the drawing.

4. Bad Hcad_Toolbox.dll file eBadLinetypName V53.04

Card 480 View Build 3D Risers (AutoCAD Based) Insert Fitting Via Parts Tree None Unhandled Exception

3dends folder or files missing unhandled exception

Card 249 View Couplings (AutoCAD Based) Insert Couplings None None

Interestingly PDMODE is set to 1. This means that there is no node point at the insertion of these sizes, so the sizes are not found.

Card 307 View Calculations (AutoCAD Based) Start Autocalcs None None

All pipe is in the branch line (SPRKDATB) layer solid pipes 3d modeling

Card 306 View Calculations (AutoCAD Based) Start Autocalcs None None

Setting incorrect

Card 370 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None None

1. dry pendent sprinkler is defined in the drawing and cannot be generated as Revit content Retrieve content Revit revit Link 4-2

Card 411 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None None

Unknown, but likely that creation of Revit content will still be accomplished.

Card 186 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

AutoCAD Error Aborting FATAL ERROR: Unhandled Access Violation Reading 0x00e0 Exception at [hex code here] Acad 2019 hex code; 2D92713Eh Fatal Error

 

 

Hex code a51b726eh

Card 100 View Calculations (AutoCAD Based) Start Autocalcs Sizing Runtime Error

Runtime error 71

Runtime error 52

Card 85 View Calculations (AutoCAD Based) Start Autocalcs None None

When starting AutoCalc, the following error message appears: You have more than ONE Water Supply for these calculations... You have more then ONE Water Supply for these calculations... multiple source point

Card 117 View Calculations (AutoCAD Based) Start Autocalcs None None

Method not found: Void HCAD_HUI_CALC.Calc_SystemMatchFitting.set_XrefPipe2Handle(System String)

Card 57 View Calculations (AutoCAD Based) Start Autocalcs None None

Error matching operating head @ (xxxx.xxx, yyyy.yyy) The only option is the OK button. ALSO - The equivalent k-factor for node xxx is not an end point.

Card 59 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

Unhandled exception: ekey not found

Card 98 View Calculations (AutoCAD Based) Start Autocalcs None None

eNullObject

Card 109 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

Unhandled exception has occurred in a component in your application Index was outside the boundary of the array *APPLIES TO:* v52.05 r2, September 16 & 17 update only

Card 128 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

When trying to start the Autocalc process, the user gets a Runtime Error 7, Out of memory

Card 180 View Listing (AutoCAD Based) Listing Check Ups None None

When attempting to run AutoLIST checkups and selecting a boundary, user gets an error similar to the one below; [Exception in fs_util.arx ARX Command] Unhandled Exception C00000005 (Access Violation Writing 0x9485ad10) at address 7720F86h OR Unhandled Exception in FS_UTIL.ARX and/or ADS request. Unhandled Exception