AutoCAD Based 3D Modeling (Ribbon/Toolbar/Location)

Button: Show System Model

Description:

The CURRENT LAYER in the drawing is LOCKED. Show System Model process stops on Step 13 of 28 while adding RN Fittings to the drawing. Picking the 2D Switch to Edit Mode button removes the Hydrapipes and the riser nipples. Show System Model HydraCAD V51

Solutions:

Cause:

The CURRENT LAYER in the drawing is LOCKED. Show System Model process stops on Step 13 of 28 while adding RN Fittings to the drawing. Picking the 2D Switch to Edit Mode button removes the Hydrapipes and the riser nipples.

Solution:

Hit undo several times until the riser nipples are present. Unlock the current layer or change the current layer to any other unlocked layer. Then pick the #D Show System Model button to raise the drawing.