Hydratec Inc.

All Cards

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 398 View 3D Modeling (AutoCAD Based) Switch To Edit Mode None None

1. Important layers locked or frozen. 2. User had OPHEAD block in ACC1 layer Internal error

Card 373 View 3D Modeling (AutoCAD Based) Show System Model None None

issue with drawing dictionary making model

Card 261 View Sprinklers (AutoCAD Based) Insert Sprinkler New Symbol None

most commonly caused by dual monitor setup and laptops. NOTES: in the solution below ; the "R17.x or R18.x" string points to the version of cad you are using. R17.0 = ACAD07 R17.1 = ACAD08 R17.2 = ACAD09 After selecting "profiles" you will then pick the profile you are currently using. lock up Select new symbol Open Browse

Card 101 View Piping (AutoCAD Based) Size Pipe Setup None None

Value of 6 is not valid

Card 423 View 3D Modeling (AutoCAD Based) Show System Model None None

May have to do with sprinkler heads not defined in the drawing Exception Occured Dialog box HydraCAD

Card 633 View Piping (AutoCAD Based) Schedule Sizes None Runtime Error

When trying to open the pipe scheduler, the user gets a Runtime Error 7, Out of memory Runtime Error 7

Card 537 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Important layers such as SPRKDAT1 through SPRKDAT4 are lower case instead of upper case. 3d modeling

Card 286 View Piping (AutoCAD Based) Schedule Sizes None None

Possible bad ceiling defline

Card 349 View Piping (AutoCAD Based) Riser Nipple Setup None None

Visual style set to something other than 2dWireframe

Card 376 View Listing (AutoCAD Based) Listing Check Ups None None

Unknown Calculations toolb 51

Card 450 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

1) 3D Details cannot handle a main with more than 9 sections. 2) May have a dot in ID name. (ex. SP.1) missing outlets Inserting Mains

Card 462 View Piping (AutoCAD Based) Size Pipe Setup None None

When trying to size a pipe, you select the pipe and nothing happens or you get an 'Automation Error' message

Card 332 View Piping (AutoCAD Based) Size Pipe Setup None None

ATTDISP setting is wrong.

Card 361 View 3D Modeling (AutoCAD Based) Show System Model None None

so far this has only been a problem with AutoCad Mechanical - bad support path entries Acad Mechanical

Card 510 View Calculations (AutoCAD Based) Figure Head Area None None

Sprinkler blocks must have a Z coordinate equal to zero inches. Dialog box All

Card 526 View Calculations (AutoCAD Based) Reference Points None None

Bad ref point block Dialog box

Card 483 View 3D Modeling (AutoCAD Based) Show System Model None None

The rotation of the sprinkler head symbol in the DETAILS layer is the cause of the problem. After using SFS - The sprinkler connector for the side outlet flex is rotated to the same angle as the sprinkler head symbol in the DETAILS layer. show flexible sprinkler

Card 282 View 3D Modeling (AutoCAD Based) Show System Model None Unhandled Exception

missing layer Unhandled Exceptio

Card 291 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Pipex block is purged from drawing. save after 3d to 2d

Card 497 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None None

Sprinkler heads were not properly defined with a part number within the HydraCAD drawing. Therefore, Revit used a default sprinkler head symbol which happened to be a pendent sprinkler symbol. Revit