Card 448 View Sprinklers (AutoCAD Based) Insert Sprinkler Define Head None

Unknown but HydraHeads is having problems using Nitro Pro to view the PDF files n/a Viewing PDF 50.19.3

Card 151 View Listing (AutoCAD Based) Start Autolist None None

No error , main tagged as welded fab gets listed as threaded material with an Auto Line Number inserted at a riser nipple where the main changes elevation. not listed missing as a line in lines listed as threaded auto line tag autoline tag auto tag none

Card 301 View 3D Modeling (AutoCAD Based) Show System Model None Unhandled Exception

1. top of structure blocks have disassociated themselves from the top of structure definition lines. unhandledexception

Card 490 View HydraCALC (AutoCAD Based) Calculate None No Connectable Heads

Old or invalid plotters and plot styles (believe it or not) Slow Opening/Using Slow

Card 420 View Persistent Model (AutoCAD Based) None None None

Duplicate objects are on the drawing and Acad can't write an identical object to the hash table. n/a Dialog Box 53.01 r2

Card 529 View Persistent Model (AutoCAD Based) Navis Model None None

unknown, this shouldn't be happening n/a Navis model n/a

Card 488 View Persistent Model (AutoCAD Based) None None None

1. there are 3d solids in the drawing that have no geometry. Persistent Model

Card 105 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Running an AutoCALC, it hangs at step 1a.3 while attaching fittings and you get a Runtime Error 5

 

Card 451 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

Incorrect Support File Search Path folder locations Error dialog box insert fitting

Card 106 View Calculations (AutoCAD Based) Calc Check Ups None None

Duplicate Reference Points with jump detour

Card 402 View Calculations (AutoCAD Based) Start Autocalcs None None

Process is crashing out because an old vertical pipe block is in the drawing DRYVOL or DV HydraCAD V50+

Card 384 View Sprinklers (AutoCAD Based) Head Schedule None None

If the user runs the sprinkler head schedule, the dry volume text window will not appear. DRYVOLU or DV HydraCAD 52.03 r1

Card 243 View Piping (AutoCAD Based) Riser Nipple Setup None None

Hydrapipes apparently use Standard as their Style and the menu macro no longer changes Standard, only the Style named Hcad

Card 150 View Listing (AutoCAD Based) Start Autolist None None

V45 converted to V50, the hangers show up in list but no cut dimensions on drawing

Card 160 View Listing (AutoCAD Based) Start Autolist None None

nil

Card 470 View 3D Modeling (AutoCAD Based) Show System Model None None

The last sprinkler head setup as sprigs on sloped pipe will most likely show a cap length shorter than the 'flat' length. For instance, a 3" capped pipe is returning from 3D as 2" rather than a longer length. n/a Plan View n/a

Card 372 View Couplings (AutoCAD Based) Insert Couplings None None

Program has become "tired"

Card 549 View 3D Modeling (AutoCAD Based) Show System Model None None

Drawing zooms out to expected isometric view as if 3D System Model has been completed. No 3D Pipe can be found. Unknown cause No 3D Pipe Seen All

Card 270 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Video Driver out of Date -or- 2. AutoCAD MEP has a .dbx file interfering with our drawing HydraCAD

Card 272 View 3D Modeling (AutoCAD Based) Show System Model None None

The CURRENT LAYER in the drawing is LOCKED. Show System Model process stops on Step 13 of 28 while adding RN Fittings to the drawing. Picking the 2D Switch to Edit Mode button removes the Hydrapipes and the riser nipples. Show System Model HydraCAD V51