Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
AutoCAD Based Steel (Ribbon/Toolbar/Location)
Description:
when placing a TOS defline and a item is picked to place the Tos defline. If the item has a Z coordinate then this can be assinged the TOS block. the defline will be a 0 but the blocks will be elevated (although it looks normal) this will usually raise once and then the error will occur even if you put a new defline in. tos id missing
when placing a TOS defline and a item is picked to place the Tos defline. If the item has a Z coordinate then this can be assinged the TOS block. the defline will be a 0 but the blocks will be elevated (although it looks normal) this will usually raise once and then the error will occur even if you put a new defline in.
Open properties Pick the funnel in the upper rt corner set the following options. Apply to = Entire drawing Object type=Block Reference Properties= Name Operator = =Equals Value= Tos include a new selection set is checked pick ok You will see the block reference show up in the properties window. Under "Geometry" change the Position Z to 1 pick another cell and then go back and change the Position Z to 0. (autocad does not like a setting of 0 unless you set it to 1 first) this should raise again