Card 1027 View | HydraCALC (Standalone) | Open | Open | Requested Operation Requires Elevation | When trying to open a .WXF file by double-clicking it, you get this error message; "The requested operation requires elevation"
The file can be opened if using HydraCALC to open the file by going to the menu [File|Open] |
|
Card 1021 View | HydraCALC (Standalone) | Open | Double-Click | None | Double-clicking your HydraCALC icon makes nothing happen. You do not see HydraCALC open onscreen nor on your taskbar.
If you open your task manager and see the app "Hyd_prog.exe" open but not on your taskbar, then the application is stuck in purgatory. If you see entries here, use END TASK to get rid of them. Scroll into BACKGROUND PROCESSES as well as they may not show up in "Apps"
Another possibility may be that it's on the taskbar but not on your screen. That means it's open but offscreen. See this HydraCARD to fix that issue; HydraCARD 565 only AFTER you've checked on the solution below.
|
|
Card 986 View | HydraCALC (Standalone) | Calculate | Calculation Results | Pressure Required Is Negative | When running a calculation, the value for "pressure required" shows a negative value.
|
|
Card 979 View | HydraCALC (Standalone) | Calculate | Calculation Results | System Is -Nan(Ind) Psi | After calculating the system, the results show, "Your System Has a Deficit" System is -nan(ind) psi over the Water Supply Curve |
|
Card 976 View | HydraCALC (Standalone) | None | None | HydraCALC is calculating the equivalent lengths wrong
|
||
Card 968 View | HydraCALC (Standalone) | Print Final | None | Runtime Error | HydraVIEW default printer 'yourprinternamehere' was not found, resetting to Windows default. Then possibly a runtime error 62, Input past end of file |
|
Card 961 View | HydraCALC (Standalone) | Calculate | Add New Authorization | Disconnected Pipe | **Trying to calculate a job which was generated from HydraCAD**, you get this error on the first attempt to calculate; 'disconnected pipe' |
|
Card 953 View | HydraCALC (Standalone) | Calculate | Add New Authorization | Source Calc | When trying to run a source calc calculation (find the maximum possible denisity) with a pump as one of the water supplies, you get the error message;
A source calc cannot be performed if a pump is present. Please remove the pump or uncheck 'Source Calc' to continue. |
|
Card 951 View | HydraCALC (Standalone) | None | None | Runtime Error | Trying to run a calculation gets a Runtime error 13, Type mismatch |
|
Card 941 View | HydraCALC (Standalone) | None | None | Runtime Error | You get a runtime error 13 after clicking OK on the results window.
|