Standalone (Hydracalc)
Total: 92
Page:
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 1405 View | HydraCALC (Standalone) | Calculate | Calculation Results | Calculation Will Not Continue | When trying to run the calculation, you get the message, "The system flow demand of ### exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO. The calculation will not continue"
But your flow is a very large number |
|
Card 1401 View | HydraCALC (Standalone) | Calculate | Calculating | None | When running a Darcy-Weisbach calculation, after changing your k-factor, the program will not ask to Modify K-Factor anymore The calculation method you have chosen is only a legal calculation method under NFPA 13 rules for anti-freeze systems and requires modified k-factors Have the k-factors already been modified |
|
Card 1395 View | HydraCALC (Standalone) | Calculate | Calculating | Runtime 5 | When clicking the Calculate button or the OK button from the Pre-Calc Questions window, you get a Runtime-error 5, Run-time error '5': Invalid procedure call or argument |
|
Card 1384 View | HydraCALC (Standalone) | None | None | Runtime 6 | When editing the cells, you receive the error Run-time error '6', Overflow |
|
Card 1373 View | HydraCALC Sizer (Standalone) | None | None | Run-Time Error 9 | When hitting Save, Refresh Drawing or Calculate Results, user gets a Run-time 9 error. AKA Subscript out of Range |
|
Card 1367 View | HydraCALC (Standalone) | Open | Runtime 62 | Runtime 62 | When trying to open a calc job using [File|Open], you get a Run-time error '62': Input past end of file |
|
Card 1362 View | HydraCALC Sizer (Standalone) | Open | None | Runtime Error | When opening HydraCALC SIZER, you get the error; Run-time error '53': File not found |
|
Card 1339 View | HydraCALC (Standalone) | Calculation Process | None | None | Dup Equiv K / Sys Pipe Node |
|
Card 1332 View | HydraCALC (Standalone) | Calculate | Calculation Results | None | The View button that appears after running a calculation does not do anything Or you get the error; C:\Windows\system32\Write.exe 'file name asked for does not exist! |
|
Card 1309 View | HydraCALC (Standalone) | Calculate | None | None | No error but the calculation process takes a very long time and is slow. The process hangs and usually the RAM runs up to 100%. You'll likely hear the computer's fan rev up.
|
Page: