Hydratec Inc.

AutoCAD Based Cards

Total: 708

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 76 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Run-time error 76 Also happens when trying to open the SIZING window in the Calc Setup screen.

Card 40 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Runtime Error

Runtime Error 5 1.A.1

Card 108 View Calculations (AutoCAD Based) Start Autocalcs None None

When attempting to run AutoCALC, a message on the command prompt says, "hcad_acd file not found"

Card 68 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 5a.3e - Path/File Read Error

Card 46 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 1a.1 - You may be missing a selected pipe type from master.dat or no pipe type has been selected for a particular system component

Card 44 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

After calc area # is picked - dialog box runs through gathering information and closes with message "Failed to create file to send to calcs....Exiting"

Card 80 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

Unhandled Exception: eWasErased Finishing an Area after calculating. Hangs up in Size Pipe from Schedule

Card 126 View Calculations (AutoCAD Based) Start Autocalcs None None

When starting the AutoCALC process, you get the error Unhandled exception has occurred in a component of your application

Key cannot be null

Parameter name: key.

Expanding DETAILS shows this information;

Application does not support just-in-time (JIT)
debugging. See the end of this message for details.

************** Exception Text **************
System.ArgumentNullException: Key cannot be null.
Parameter name: key
   at System.Collections.Hashtable.Insert(Object key, Object nvalue, Boolean add)
   at HCAD_HUI_CALC.CalcClass_Utilities.GetNodesOfPipesThatAreVertical(String FitID, Calc_File myCalcFile)
   at CalcingNameSpace.AutoCalcForm.MakeCalcFiledataPart1(Database db, Calc_File& MyCalcFile)
   at CalcingNameSpace.AutoCalcForm.SetupCalcFile()

Card 103 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 9a.1 - Runtime Error 62 Input past end of file.

Card 110 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 9a.1 - Saving Raw Calc Data Auto- Program Load Error Could not initiate process called for by \Hes\HydraCalc\Ver50\Programs\Hyd_Prog.exe

Page: