Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 179 View Listing (AutoCAD Based) Start Autolist None None

Error No Tags Found No Tags Found

Card 145 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

Unhandled exception: eNullobjectId Application does not support just-in-time (JIT)

Card 116 View Listing (AutoCAD Based) Listing Check Ups None Unhandled Exception

When attempting to run AutoLIST checkups and selecting a boundary, user gets an error similar to the one below; [Exception in fs_util.arx ARX Command] Unhandled Exception C00000005 (Access Violation Writing 0x9485ad10) at address 7720F86h OR Unhandled Exception in FS_UTIL.ARX and/or ADS request.

Card 177 View Listing (AutoCAD Based) Start Autolist None None

Field is too small to accept the amount of data you attempted to add. Try inserting or pasting less data. Runtime Error

Card 182 View Listing (AutoCAD Based) Start Autolist None None

Run-time error 70 Permission denied Runtime Error 70

Card 168 View Listing (AutoCAD Based) Start Autolist None None

HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method

Card 186 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

AutoCAD Error Aborting FATAL ERROR: Unhandled Access Violation Reading 0x00e0 Exception at [hex code here] Acad 2019 hex code; 2D92713Eh Fatal Error

 

 

Hex code a51b726eh

Card 180 View Listing (AutoCAD Based) Listing Check Ups None None

When attempting to run AutoLIST checkups and selecting a boundary, user gets an error similar to the one below; [Exception in fs_util.arx ARX Command] Unhandled Exception C00000005 (Access Violation Writing 0x9485ad10) at address 7720F86h OR Unhandled Exception in FS_UTIL.ARX and/or ADS request. Unhandled Exception

Card 183 View Listing (AutoCAD Based) Start Autolist None None

When attempting to run AutoLIST, an error message says; Error: Unable to insert cut length dimensions! Unable to insert cut 

 

You may also see this message;

Re-run Autolist with the drawing starting on the ground, Current run will not include any FSC information in the MISC tab in HydraLIST

Card 185 View Listing (AutoCAD Based) None None Runtime Error

When trying to load into FIG Trees, user will either get a; Runtime Error 6 (Overflow) or; Error in Form 4 - Form Load, the application cannot continue Runtime Error 6