AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist

Description:

Head block definition is correct but the wrong sprinkler head thread size is reported in HydraLIST. Wrong welded outlet size for sprinkler heads are reported in HydraLIST. head sprinkler outlet size thread none

Solutions:

Cause:

Sprinkler head blocks were created incorrectly. Because the head blocks were created incorrectly AutoLIST did not recognize the complete definition.

Solution:

Start with a HydraCAD sprinkler head block and edit the block to look as you wish. Then save with the new name. Create block with color set to "BY BLOCK". (allows change of color easily). Avoid HATCH patterns to keep drawing size small using many typical heads. The layer MUST be SPRNKS. The name MUST have at least 4 characters. (no spaces allowed).

Updated: Feb. 14, 2024, 3:17 p.m. Created: March 1, 2019, midnight