AutoCAD Based Cards
Total: 697
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 1320 View | Listing (AutoCAD Based) | Start Autolist | Hydralist Opens | None | After running an Autolist, in HydraLIST and the LINES tab you have a listing tag ID called RM |
|
Card 1278 View | Listing (AutoCAD Based) | Start Autolist | None | Missing Pipe Dimension | After Autolist has run, your drawing doesn't display any cut pipe dimensions. Only cut vertical pipes/riser nipples are visible, but not the megenta PIPEX block
|
|
Card 1191 View | Listing (AutoCAD Based) | Start Autolist | None | Fatal Error | When attempting to 'Start AutoLIST' (SAL command), user gets an AutoCAD Fatal Error.
|
|
Card 1164 View | Listing (AutoCAD Based) | Start Autolist | None | File To Load Paths And Dirs. | When starting the listing process, you get this error File Location Error Please browse to set stocklist location. It must be a valid path. Then try again |
|
Card 1163 View | Listing (AutoCAD Based) | Listable Dynamic Block | None | Registry Problem | Trying to open Listable Dynamic Blocks and you get this error message
The problem is, you already have a newer version.
Go to HydraLIST, click [Help|About HydraLIST] to confirm. |
|
Card 1039 View | Listing (AutoCAD Based) | Start Autolist | None | Internal Error: Enotopenforwrite | When running an AutoLIST, you get the error;
AutoCAD Error Aborting INTERNAL ERROR: eNotOpenForWrite message
|
|
Card 946 View | Listing (AutoCAD Based) | Start Autolist | None | None | When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing. It only shows the original tag of MAIN A Same can be said for line tags #LN1.1, #LN1.2, etc |
|
Card 854 View | Listing (AutoCAD Based) | Start Autolist | None | Hydracad Error | When starting the AutoLIST process, the message box shown below pops up. The process "pretends" to continue through, but when HydraLIST opens, it's completely blank. |
|
Card 166 View | Listing (AutoCAD Based) | Start Autolist | None | None | When starting the AutoLIST process, it sits there normally then you get this error message.
You have canceled. There is nothing to stocklist
|
|
Card 298 View | Listing (AutoCAD Based) | Start Autolist | None | None | DAO server error |