| Card 80 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Unhandled Exception | Unhandled Exception: eWasErased Finishing an Area after calculating. Hangs up in Size Pipe from Schedule |
|
| Card 79 View | Calculations (AutoCAD Based) | Calc Check Ups | None | None | During checkups, the process abruptly ends and reports "Exception occurred" on the command prompt |
|
| Card 76 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Run-time error 76 Also happens when trying to open the SIZING window in the Calc Setup screen. |
|
| Card 75 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Drawing seems fine with no errors but opens to a blank HydraCALC screen |
|
| Card 74 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Step 2.3 - After one pass through calculations Miscfunc hangs.... Also possibly "Hydraulic Engine not responding" and a "Runtime Error 62 input past end of file" |
|
| Card 73 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | eLockViolation elock |
|
| Card 71 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | When starting AutoCALC, it stops in the v50 Fuel Gauge at step 1a.4 - Calculating Total Lengths. Working on the pipe from node #### to node #### with a fitting string of ...
May be followed by a Runtime Error 13 or Runtime Error 5 Your first step of troubleshooting should be to track down the coordinates of the handles (the 4 to 6 character hex code noted after the word node, or pipe, or fitting. Search for the command FINDME to get these coordinates. |
|
| Card 70 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Duplicated Hydraulic Ref Point |
Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID Duplicated hydraulic ref points
|
|
| Card 69 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Step 1a.10 - Two windows will be visible: 1. Attaching Node (X) Elevations and 2. Error Display "Missing Pipe Type". You will also see Ref1 & Ref2 values (for the pipe handle). *Make a note of each Ref1 value. See Solution 3a under Solution/Notes if applicable. |
|
| Card 68 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Step 5a.3e - Path/File Read Error |
|