Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Message | ||
Card 1155 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the external command... x must be a finite number |
|
Card 1156 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the external command... Autodesk.Revit.Exceptions.InvalidObjectException |
|
Card 1261 View | HydraCAD (Revit Based) | Cleanup Tags | None | None |
|
|
Card 167 View | Listing (AutoCAD Based) | Start Autolist | None | None | Some threaded branch lines are not being tagged automatically as expected. Automatic Line Tags are missing after running AutoLIST. none |
|
Card 381 View | Listing (AutoCAD Based) | New Tag | None | None | ??? Error when picking NewTag button. Connection Failed listing tags |
|
Card 169 View | Listing (AutoCAD Based) | Start Autolist | None | Dao Error | Call from Autolist::CleanUpLinesDatabase(lineDB) DAO error DAO error |
|
Card 94 View | Calculations (AutoCAD Based) | Calc Check Ups | None | None | Upon starting the Checkup command for AutoCalc, the command starts but stops. The Command Prompt says; "Initializing... Checking to make sure heads are in the right layer...bad argument type: stringp nil" As a side note, the user's drawing had multiple repeat head definition boxes (blue boxes in ACC1 layer). These were cleaned up (deleted) and the heads redefined. The AUDIT command was run after the cleanup |
|
Card 179 View | Listing (AutoCAD Based) | Start Autolist | None | None | Error No Tags Found No Tags Found |
|
Card 293 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | ??? Connection Failed listing tags |
|
Card 1069 View | Build 3D Risers (AutoCAD Based) | Create Legend | None | Unhandled Exception | After creating a legend for your 3D riser, you use the ILT command to insert a legend tag. It inserts the tag, but you get the error. You have to click CONTINUE then repeat the command to place another one. Unhandled exception has occurred in a component in your application Arithmetic operation resulted in an overflow Application does not support just-in-time (JIT) |
|
Card 181 View | Listing (AutoCAD Based) | Start Autolist | None | Dao Error | Call from 'AutoList::CleanupDatabase (hangerHeaderDB)' DAO Error The changes you requested to the table were not successful.... DAO error |
|
Card 946 View | Listing (AutoCAD Based) | Start Autolist | None | None | When running an autolist, you're no longer getting the listing tag IDs such as MAIN A.1, MAIN A.2, MAIN A.3, etc show up on your drawing. It only shows the original tag of MAIN A Same can be said for line tags #LN1.1, #LN1.2, etc |
|
Card 1141 View | HydraCAD (Revit Based) | Tag Pipes | None | Command Failure For External Command | Revit could not complete the External Command... System.NullReferenceException |
|
Card 906 View | HydraCAD (Revit Based) | Pretty Sprinklers | None | None | The following sprinkler tags are not loaded ... |